Pilot manikin study showed that a supraglottic airway device improved simulated neonatal ventilation in a low‐resource setting
نویسندگان
چکیده
AIM We compared the performance of personnel in a low-resource setting when they used the I-gel cuffless neonatal laryngeal mask or a face mask on a neonatal airway management manikin. METHODS At Mulago Hospital, Uganda, 25 doctors, nurses and midwives involved in neonatal resuscitation were given brief training with the I-gel and face mask. Then, every participant was observed positioning both devices on three consecutive occasions. The success rate and insertion times leading to effective positive pressure ventilation (PPV) were recorded. Participants rated the perceived efficiency of the devices using a five-point Likert scale. RESULTS The I-gel achieved a 100% success rate on all three occasions, but the face mask was significantly less effective in achieving effective PPV and the failure rates at the first, second and third attempts were 28%, 8% and 20%, respectively. The perceived efficiency of the devices was significantly superior for the I-gel (4.7 ± 0.4) than the face mask (3.3 ± 0.8). CONCLUSION The I-gel was more effective than the face mask in establishing PPV in the manikin, and user satisfaction was higher. These encouraging manikin data could be a stepping stone for clinical research on the use of the I-gel for neonatal resuscitation in low-resource settings.
منابع مشابه
A Comparison of Three Different Supraglottic Airway Devices in Neonatal Airway Training during Resuscitation Simulation
Objective: The aim of this study was to compare the success rates for insertion using the laryngeal mask, laryngeal tube, and I-gel supraglottic airway devices in a neonatal airway manikin during a resuscitation simulation course. Methods: Three groups of health care professionals were given a brief supervised training in using the devices. For each participant the positioning of each device wa...
متن کاملComparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries
Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...
متن کاملEvaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices.
We evaluated the performance of four currently available manikins: Airway Management Trainer (Ambu, UK), Airway Trainer (Laerdal, Norway), Airsim (Trucorp, Ireland), 'Bill 1' (VBM, Germany), with eight supraglottic airway devices: Airway Management Device, Cobra Perilaryngeal Airway, Combitube, i-Gel, Laryngeal Tube, Laryngeal Tube Disposable, Laryngeal Tube Suction II and Streamlined Liner of ...
متن کاملAirway management in simulated restricted access to a patient - can manikin-based studies provide relevant data?
BACKGROUND Alternatives to endotracheal intubation (ETI) are required when access to the cranial end of the patient is restricted. In this study, the success rate and time duration of standard intubation techniques were compared with two different supraglottic devices. Two different manikins were used for the study, and the training effect was studied when the same manikin was repeatedly used. ...
متن کاملInfluence of airway management strategy on "no-flow-time" during an "Advanced life support course" for intensive care nurses – A single rescuer resuscitation manikin study
BACKGROUND In 1999, the laryngeal tube (VBM Medizintechnik, Sulz, Germany) was introduced as a new supraglottic airway. It was designed to allow either spontaneous breathing or controlled ventilation during anaesthesia; additionally it may serve as an alternative to endotracheal intubation, or bag-mask ventilation during resuscitation. Several variations of this supraglottic airway exist. In ou...
متن کامل