Impact of Porosity and Electrolyte Composition on the Surface Charge of Hydroxyapatite Biomaterials.
نویسندگان
چکیده
The success or failure of a material when implanted in the body is greatly determined by the surface properties of the material and the host tissue reactions. The very first event that takes place after implantation is the interaction of soluble ions, molecules and proteins from the biological environment with the material surface leading to the formation of an adsorbed protein layer that will later influence cell attachment. In this context, the particular topography and surface charge of a material become critical as they influence the nature of the proteins that will adsorb. However, very limited information is available on the surface charge of porous substrates. Only until very recently was the determination of the zeta potential on porous membranes accurately determined. The goal of this work was to implement the previous findings for the determination of the zeta potential of a series of porous hydroxyapatite (HA) substrates and to assess how porosity affects the measurements. In addition, studies using various electrolytes were also performed to prove how the specific affinity of certain ions for HA can further impact surface charge. The results showed that all materials exhibited very similar external surface charge (approximately -23 mV), consistent with their almost identical topographies. However, the presence of interconnected pores underneath the sample surface resulted in an additional internal zeta potential that varied with the porosity content. Measurements with different electrolytes confirmed the selectivity of divalent ions for HA underlying the importance of testing biomaterials using relevant electrolytes.
منابع مشابه
The effect of sulfuric acid on pore initiation in anodic alumina formed in oxalic acid
In this work, a tracer study on pore initiation in anodic alumina in oxalic acid was performed. Effects of some experimental parameters such as applied electrical potential, electrolyte composition and heat pretreatment were evaluated. Electrochemical and morphological experiments were performed using potentiostatic anodizing and scanning electron microscopy (SEM) techniques, respectively. Effe...
متن کاملEffect of coating time on the corrosion behavior of ceramic coatings containing hydroxyapatite nanoparticles by plasma electrolytic oxidation method on AZ31 Mg alloy in simulated body fluid
In this study, the effect of coating time on the microstructure and corrosion behavior of AZ31 Mg alloy coated by plasma electrolytic oxidation (PEO) method has been investigated. For this purpose, phosphate-based electrolyte containing hydroxyapatite nanoparticles was used at different times of 5, 10 and 15 minutes. The surface properties and chemical composition of the coatings were investiga...
متن کاملEffect of composition electrolyte on the morphology and photocatalytic activity of anodized titanium nanoporous
The morphology of titanium dioxide and titanium dioxide-tungsten trioxide nanocomposite films fabricated by anodizing in a glycerol solution containing 0.13 M NH4F and different quantity of Na2WO4 was investigated as a function of sodium tungstate concentrations. The effects of sodium tungstate concentration on the surface morphology were observed by scanning electron microscopy (SEM). It was c...
متن کاملPhysicochemical characterization of biomaterials commonly used in dentistry as bone substitutes--comparison with human bone.
The present work focuses on the physicochemical characterization of selected mineral-based biomaterials that are frequently used in dental applications. The selected materials are commercially available as granules from different biological origins: bovine, porcine, and coralline. Natural and calcined human bone were used for comparison purposes. Besides a classical rationalization of chemical ...
متن کاملThe Effect of Rotation Speed and Time of Milling on Synthesis and Properties of Fluoridated Hydroxyapatite Biomaterial
Synthetic hydroxyapatite (HA) is the most helpful because of its similarity to natural bone in both crystalline structure and chemical composition. Recently, fluoridated hydroxyapatite (FHA) has been developed in dental and orthopedic application because it has lower solubility than pure HA, while maintaining the comparable bioactivity and biocompatibility. The aim of this study was to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- ACS applied materials & interfaces
دوره 8 1 شماره
صفحات -
تاریخ انتشار 2016