Mechanisms isolated by frequency-doubling technology perimetry.

نویسندگان

  • Andrew John Anderson
  • Chris A Johnson
چکیده

PURPOSE The frequency-doubling (FD) phenomenon describes the increase in apparent spatial frequency occurring when low-spatial-frequency sine wave gratings undergo rapid counterphase flicker. It is unclear whether the visual mechanisms isolated when pattern appearance is used as a threshold criterion are the same as when a simple detection criterion (as in FD perimetry) is used. It is also unclear whether the FD stimulus isolates mechanisms that differ from those isolated by spatially uniform flicker. In the current study, adaptation and spatiotemporal tuning functions were determined, using the FD stimulus, uniform flicker, and static (nonflickering) grating targets, to establish whether distinct mechanisms are isolated by the FD stimulus. METHODS Spatiotemporal tuning functions were determined in six observers, using an FD stimulus under conditions of detection and resolution and using spatially uniform flickering stimuli and static grating stimuli. The effect of light adaptation on these stimulus classes was also assessed. All stimuli were 10 degrees-wide squares. RESULTS Spatiotemporal tuning functions and adaptation characteristics were identical for both the FD detection and resolution paradigms. Spatially uniform flicker gave indistinguishable tuning functions and adaptation characteristics to the FD stimulus at 25 Hz and higher, but differed below this frequency. Static grating stimuli differed from FD stimuli in both tuning functions and adaptation characteristics. CONCLUSIONS Absolute detection of the FD stimulus involves mechanisms that are indistinguishable from those involved when a criterion based on spatial form (i.e., resolution of a pattern) is used, indicating that a simple detection criterion can be used in FD perimetry. The FD stimulus isolates similar mechanisms to spatially uniform flickering stimuli at high temporal frequencies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Agreement and correlation between the frequency doubling perimetry and the blue-yellow perimetry in glaucoma: no support for selective damage].

PURPOSE To test the agreement and correlation between the frequency doubling technology and the short wavelength perimetry in glaucoma. METHODS Glaucoma patients were selected from the Glaucoma Sector of CEROF - Universidade Federal de Goiás, and then underwent frequency doubling technology and short wavelength perimetry examinations in both eyes (if eligible) on the same day in a random sequ...

متن کامل

Frequency Doubling Perimetry

DOS Times Vol. 11, No. 6 December, 2005 The goal of perimetry is to establish an accurate estimate of visual field sensitivity. Perimetry is performed to detect early visual field defects, determine specific patterns of visual field loss for differential diagnosis and monitor for evidence of progression of field loss. Conventionally Standard Achromatic Perimetry (SAP) has been used to achieve t...

متن کامل

Frequency doubling technology perimetry for detection of glaucomatous visual field loss.

PURPOSE To evaluate the ability of frequency doubling technology perimetry to detect early, moderate, and advanced glaucomatous visual field loss. METHODS In a prospective study, frequency doubling technology perimetry (C-20 full threshold) was performed in the right eye of 254 normal control subjects and 230 patients with early (n = 85), moderate (n = 114), or advanced (n = 31) glaucomatous ...

متن کامل

Screening for glaucoma with frequency-doubling technology and Damato campimetry.

OBJECTIVE To assess frequency-doubling technology (FDT) perimetry (Humphrey Systems, San Leandro, Calif) and Damato campimetry (Precision Vision, Villa Park, Ill) for detecting glaucoma in a public glaucoma screening. METHODS A 2-day public glaucoma screening was held at 2 different institutions. Each subject underwent 2 visual field screening tests (Damato campimetry and FDT perimetry in scr...

متن کامل

Frequency Doubling Technology vs Standard Automated Perimetry in Ocular Hypertensive Patients

BACKGROUND Frequency doubling technology (FDT) perimetry measures contrast sensitivity. The magnocellular component of ganglion cells in human retina is isolated as a whole by the FDT stimulus. The aim of this study is to investigate the role of Humphrey Matrix threshold testing in the detection of early functional retinal impairment in ocular hypertensive patients compared to standard automate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 43 2  شماره 

صفحات  -

تاریخ انتشار 2002