Cementing techniques in hip resurfacing.
نویسندگان
چکیده
The subject of the cementing technique in hip resurfacing has been poorly studied to date. The hip resurfacing prosthesis is unique in the family of cemented prostheses because the cement mantle is blind (hidden underneath the implant) and is radiographically obscured. This presents an immediate challenge to the surgeon at the time of surgery, but also has a longer-term implication in terms of lack of post-operative clinical observation. This should be compared with total hip replacement or total knee replacement where the cement mantle can at least be partially observed both intra- and post-operatively. With this in mind, the objective of this review is, firstly, to understand the cement mantles typically achieved in current clinical practice and, secondly, to identify those factors affecting the cement mantle and to consolidate them into an improved and reproducible cementing technique. The outcome of this work shows that the low-viscosity technique can commonly lead to excessive cement penetration in the proximal femoral head and an incompletely seated component, whereas a more consistent controlled cement mantle can be achieved with a high-viscosity cementing technique. Consequently, it is recommended that a high-viscosity technique should be used to minimize the build-up of excessive cement, to reduce the temperature created by the exothermic polymerization, and to help to ensure correct seating of the prosthesis. A combination of these factors is potentially critical to the clinical success of some articular surface replacement (ASR) procedures. It is important to note that we specifically studied the DePuy ASR system; therefore only the general principles (and not the specifics) of the cementing technique may apply to other resurfacing prostheses, because of differences in internal geometry, clearance, and surgical technique.
منابع مشابه
Hip resurfacing arthroplasty: current status and future perspectives.
Hip resurfacing arthroplasty (HRA) is a concept of hip replacement that allows treating young active patients with a femoral bone preserving procedure. The proposed advantages of resuming an active lifestyle with increased frequency and duration of sports activities have been shown to be realistic. The 30-year cost-effectiveness in young male patients has been shown to be higher in resurfacing ...
متن کاملAnisotropic bone remodeling of a biomimetic metal-on-metal hip resurfacing implant.
Hip resurfacing (HR) is a highly attractive option for young and active patients. Some surgeons have advocated cementing the metaphyseal stem of the femoral component to improve fixation and survivorship of HR. However, extending component fixation to the metaphysis may promote femoral head strain shielding, which in turn may reduce survival of the femoral component. Replacing the metallic meta...
متن کاملOutcomes of Charnley total hip arthroplasty using improved cementing with so-called second- and third-generation techniques
BACKGROUND Techniques of cemented total hip arthroplasty have developed over time. We present the outcomes of Charnley total hip arthroplasty performed using improved second- and third-generation cementing techniques. METHODS We reviewed the radiologic results of 91 Charnley total hip arthroplasties performed using second- and third-generation cementing techniques. Second-generation technique...
متن کاملFactors affecting the cement penetration of a hip resurfacing implant: an in vitro study.
An understanding of how the cementing technique influences cement penetration is important for surgeons to plan and conduct hip resurfacing procedures. Therefore the aim of this study is to determine the influence of the following parameters on cement penetration: use of pulse lavage, type of cement, and the standing period of the cement. Nine fresh frozen paired whole cadaver femora were used ...
متن کاملThe effect of improved cementing techniques on component loosening in total hip replacement. An 11-year radiographic review.
Improved cementing techniques have been shown to decrease the rate of aseptic loosening of femoral components of cemented total hip replacements at five to seven years. We now report our results in 105 hips in 93 patients at 10 to 12.7 years (mean 11.2). The improved techniques included use of a medullary plug, a cement gun, a doughy mix of Simplex P and a collared stem of chrome cobalt. Only t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
دوره 220 2 شماره
صفحات -
تاریخ انتشار 2006