Contact sensitivity analysis of FE model of the pelvis with press-fit acetabular prosthesis

ثبت نشده
چکیده

Introduction Lack of primary stability has been regarded as a major cause for implant loosening in total hip arthroplasty. For a cementless press-fit acetabular cup, primary stability is achieved by inserting an oversized component into an under-reamed acetabulum. Two features that result from the press-fitting process are – 1) pre-stress due to the difference in the radii of the cup and the reamed acetabulum and 2) a gap in the polar region between the dome of the cup and the acetabulum. There are experimental studies that investigate the stability of various contact conditions of press-fit cups such as [1]. However uncertainties still remain as to what effects different contact conditions have on FE simulation results. There exist FE studies that modelled the pelvis and cementless press-fit cups together but frictional contact without press-stress or polar gap is used frequently in such studies [2]. Moreover it is not clear how different contact conditions affect load transfer patterns to the trabecular bone. This study aims to investigate these two problems.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hip Arthroplasty and its Revision in a Child: Case Report and Literature Review

Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...

متن کامل

Load Transfer across the Pelvic Bone during Normal Walking

Pre-clinical evaluations of acetabular prosthesis designs call for an accurate numerical model of the natural pelvis. Stress analysis of the pelvis during physiological loading conditions is necessary to understand the load transfer mechanism, its relation with bone morphology and to analyze the deviations in stress distributions due to implantation of the acetabulum. Despite a few experimental...

متن کامل

Subject-specific finite element model of the pelvis: development, validation and sensitivity studies.

A better understanding of the three-dimensional mechanics of the pelvis, at the patient-specific level, may lead to improved treatment modalities. Although finite element (FE) models of the pelvis have been developed, validation by direct comparison with subject-specific strains has not been performed, and previous models used simplifying assumptions regarding geometry and material properties. ...

متن کامل

The initial stability and contact mechanics of a press-fit resurfacing arthroplasty of the hip.

Finite element analysis was used to examine the initial stability after hip resurfacing and the effect of the procedure on the contact mechanics at the articulating surfaces. Models were created with the components positioned anatomically and loaded physiologically through major muscle forces. Total micromovement of less than 10 mum was predicted for the press-fit acetabular components models, ...

متن کامل

A Subject-Specific Finite Element Model of the Pelvis: Development, Validation and Sensitivity Studies

A better understanding of the three-dimensional mechanics of the pelvis, at the patientspecific level, may lead to improved treatment modalities. Although finite element (FE) models of the pelvis have been developed, validation by direct comparison with subject-specific strains has not been performed, and previous models used simplifying assumptions regarding geometry 5 and material properties....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008