Evaluation of the Thoracic Aorta with Gated CE-MRA: Technical Feasibility and Comparison with Ungated Studies

نویسندگان

  • P. Young
  • E. Williamson
  • M. Fung
  • D. Stanley
  • J. Glockner
چکیده

Purpose: 3D contrast-enhanced MRA (CE-MRA) is a widely used clinical tool for imaging thoracic aortic disease. Although CE-MRA has been shown to be very sensitive for detecting intimal flaps in aortic dissection [1], cardiac motion and aortic pulsation can significantly hinder vessel wall evaluation in the aortic root, proximal arch vessels, and proximal coronary arteries. These areas are critical to evaluate in cases of dissection, Marfan’s syndrome, and other aortic diseases. Recently, ECG-gated CE-MRA sequences have been developed, allowing high-resolution imaging with reduced motion artifact affecting these critical areas [2]. We describe our initial experience with 2 phase and 4 phase gated CE-MRA sequences, with particular attention to the sinotubular junction, aortic arch vessels, and left main coronary artery (LCA). Materials and Methods: 10 patients (7 M, 3F, age 27-82) were imaged on a 1.5 T system (GE Signa Excite) with an 8 element phased array cardiac coil for clinical indications including aneurysm (5), followup coarctation repair or bypass (2), rule out dissection (2), and rule out pulmonary AVM (1). Imaging was performed using a 2 phase (5 patients, TR/TE: 4.5/2.1 ms, FA: 35, 256x192-224 matrix, BW: 62.5 Hz/pixel, FOV: 350 mm) or 4 phase (5 patients, TR/TE: 3.84/1.8, FA: 20, 256x192-224 matrix, BW: 62.5 Hz/pixel, FOV: 350 mm) breath-hold acquisition. IV gadodiamide was injected at 3cc/sec to a total of 0.1-0.2 mmol/kg following a bolus tracking sequence. In each patient, the best phase was rated for overall image quality (excellent, good, adequate, suboptimal, or poor). Each study was further evaluated for delineation of the aortic wall at the sinotubular junction (well delineated, interface blurred by motion, motion renders nondiagnostic), delineation of the proximal arch vessels (same criteria), and delineation of the proximal LCA (well delineated, patent but not clearly seen, cannot be seen). 6 of 10 patients also had ungated MRA sequences in the same or a prior examination. In these patients, the ungated series were rated according to the same criteria. Technical issues decreasing image quality were noted. Results: In all gated studies, image quality was excellent (4), good (5), or adequate (1). The sinotubular junction was well delineated on 10/10 gated series, but blurred on 3/6 ungated series. The LCA was well delineated on 7/10 gated series, and patent but not clearly seen in the other 3/10. In contrast, the LCA could be confirmed patent in only 3/6 ungated series, and was not visualized in 3/6. In all cases, the sinotubular junction and LCA were better delineated in gated series than in their ungated comparisons. Scoring for delineation of the arch vessels was identical between gated and ungated series. All gated studies were preferred by the authors to their ungated comparisons. For the gated studies in which image quality was not excellent, problems were primarily related to long acquisition times, exceeding the patient’s breath-hold capacity. Increased intravoxel dephasing was also noted on the gated sequences, partly related to respiratory motion and higher TE values. Conclusion: ECG-gated CE-MRA offers a technically feasible method to improve image quality in thoracic aortic examination by reducing pulsation artifact and improving visualization of the aortic root and proximal coronary arteries. Limitations include incomplete breath holding during long acquisition times and increased dephasing on gated studies. 2 phase sequences, despite lower temporal resolution than 4 phase sequences, may be preferable in patients with shorter breath hold capacity, given shorter acquisition times but relatively high quality diagnostic images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation and comparison of ECG-gated techniques at 1.5 T for contrast enhanced MR angiography of the thoracic aorta

Background 3D T1-weighted contrast-enhanced MRA (CE-MRA) is routinely used for non-invasive evaluation of the thoracic aorta. However, competing demands of high spatial resolution and fast (breath-hold) acquisition often preclude ECG-gating, leading to motion artifact at the aortic root. Standard Cartesian-sampled ECG-gated CE-MRA acquires 1 partition per heartbeat resulting in long scan times,...

متن کامل

Single breath-hold non-contrast thoracic mra using highly-accelerated parallel imaging with a 32-element coil array

PURPOSE To evaluate the feasibility of performing single breathhold three-dimensional (3D) thoracic noncontrast MR angiography (NC-MRA) using highly accelerated parallel imaging. MATERIALS AND METHODS We developed a single breathhold NC MRA pulse sequence using balanced steady state free precession (SSFP) readout and highly accelerated parallel imaging. In 17 subjects, highly accelerated nonc...

متن کامل

Comparison of native high-resolution 3D and contrast-enhanced MR angiography for assessing the thoracic aorta.

AIMS To omit risks of contrast agent administration, native magnetic resonance angiography (MRA) is desired for assessing the thoracic aorta. The aim was to evaluate a native steady-state free precession (SSFP) three-dimensional (3D) MRA in comparison with contrast-enhanced MRA as the gold standard. METHODS AND RESULTS Seventy-six prospective patients with known or suspicion of thoracic aorti...

متن کامل

4-dimensional, multiphase, steady-state imaging with contrast enhancement (MUSIC) in the heart; a feasibility study in children

PURPOSE To develop a technique for high resolution, four-dimensional (4D), multiphase, steady-state imaging with contrast enhancement (MUSIC) in children with complex congenital heart disease. METHODS Eight pediatric patients underwent cardiovascular MRI with controlled mechanical ventilation after ferumoxytol administration. Breath-held contrast-enhanced MRA (CE-MRA) was performed during the...

متن کامل

Highly accelerated single breath-hold non-contrast thoracic MRA: evaluation in a clinical population

OBJECTIVES The objective of this study was to evaluate the performance of a highly accelerated breath-hold 3-dimensional noncontrast-enhanced steady-state free precession thoracic magnetic resonance angiography (NC-MRA) technique in a clinical population, including assessment of image quality, aortic dimensions, and aortic pathology, compared with electrocardiographically gated gadolinium-enhan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007