Development of a microchip Europium nanoparticle immunoassay for sensitive point-of-care HIV detection.
نویسندگان
چکیده
Rapid, sensitive and specific diagnostic assays play an indispensable role in determination of HIV infection stages and evaluation of efficacy of antiretroviral therapy. Recently, our laboratory developed a sensitive Europium nanoparticle-based microtiter-plate immunoassay capable of detecting target analytes at subpicogram per milliliter levels without the use of catalytic enzymes and signal amplification processes. Encouraged by its sensitivity and simplicity, we continued to miniaturize this assay to a microchip platform for the purpose of converting the benchtop assay technique to a point-of-care test. It was found that detection capability of the microchip platform could be readily improved using Europium nanoparticle probes. We were able to routinely detect 5 pg/mL (4.6 attomoles) of HIV-1 p24 antigen at a signal-to-blank ratio of 1.5, a sensitivity level reasonably close to that of microtiter-plate Europium nanoparticle assay. Meanwhile, use of the microchip platform effectively reduced sample/reagent consumption 4.5 fold and shortened total assay time 2 fold in comparison with microtiter plate assays. Complex matrix substance in plasma negatively affected the microchip assays and the effects could be minimized by diluting the samples before loading. With further improvements in sensitivity, reproducibility, usability, assay process simplification, and incorporation of portable time-resolved fluorescence reader, Europium nanoparticle immunoassay technology could be adapted to meet the challenges of point-of-care diagnosis of HIV or other health-threatening pathogens at bedside or in resource-limited settings.
منابع مشابه
Rapid and Sensitive Detection of Capsid Protein P24 of Human Immunodeficiency Virus Type 1 (hiv-1) Using On-chip Europium (iii) Nanoparticle-based Immunoassay
A microfluidic immunoassay based on Europium nanoparticles has been developed for rapid and sensitive detection of HIV-1. The core polymer microfluidic device contains immunoreactors anchored with monoclonal capture antibodies highly specific to p24, the capsid protein of HIV-1. To report the capturing events, biotinylated secondary antibody followed by streptavidin-conjugated Europium nanopart...
متن کاملA highly sensitive europium nanoparticle-based immunoassay for detection of influenza A/B virus antigen in clinical specimens.
We report the development of a novel europium nanoparticle-based immunoassay (ENIA) for rapid detection of influenza A and influenza B viruses. The ENIA demonstrated sensitivities of 90.7% (147/162) for influenza A viruses and 81.80% (9/11) for influenza B viruses compared to those for an in-house reverse transcription (RT)-PCR assay in testing of influenza-positive clinical samples.
متن کاملA highly sensitive europium nanoparticle-based lateral flow immunoassay for detection of chloramphenicol residue.
A europium nanoparticle-based lateral flow immunoassay for highly sensitive detection of chloramphenicol residue was developed. The detection result could be either qualitatively resolved with naked eye or quantitatively analyzed with the assistance of a digital camera. In the qualitative mode, the limit of detection (LOD) was found to be 0.25 ng/mL. In the quantitative mode, the half-maximal i...
متن کاملDevelopment of a Lateral Flow Immunoassay Using Recombinant Dense Granular Antigen (GRA) 7 to Detect Anti-Toxoplasma gondii IgG Antibodies
Toxoplasma gondii is an intracellular protozoan parasite that causes toxoplasmosis and is of medical importance in pregnant women and immunosuppressed patients. In recent years, many methods have been developed for the detection of infection caused by this parasite; however, most of the developed methods are not adequately sensitive. The dense granular antigen (GRA) ...
متن کاملDetection of anthrax toxin by an ultrasensitive immunoassay using europium nanoparticles.
We developed a europium nanoparticle-based immunoassay (ENIA) for the sensitive detection of anthrax protective antigen (PA). The ENIA exhibited a linear dose-dependent pattern within the detection range of 0.01 to 100 ng/ml and was approximately 100-fold more sensitive than enzyme-linked immunosorbent assay (ELISA). False-positive results were not observed with serum samples from healthy adult...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biosensors & bioelectronics
دوره 61 شماره
صفحات -
تاریخ انتشار 2014