Flow microsphere immunoassay-based method of virus quantitation.
نویسندگان
چکیده
A sensitive assay for adenovirus quantitation in vitro was developed using the flow microsphere immunoassay (FMIA) approach. Polystyrene microspheres were covalently coated with purified anti-adenoviral antibodies and incubated with virus-containing samples. After incubation, the samples were stained with DNA-specific fluorescent dyes, and microsphere-associated fluorescence was quantitated with a flow cytometer. The adsorption of virus to microspheres was examined under different experimental conditions. The flow cytometric assay was determined to be as accurate in detecting adenovirus as titering on 293 cells. The proposed method can be used to quantify virus in viral stocks and in biological samples.
منابع مشابه
Simultaneous detection of antibodies to cytomegalovirus and herpes simplex virus by using flow cytometry and a microsphere-based fluorescence immunoassay.
A sensitive assay for the simultaneous detection of anti-cytomegalovirus and anti-herpes simplex virus antibodies was developed. Two different sizes of polystyrene microspheres were coated with purified viral antigens. Human antiviral antibodies were detected with a biotin-streptavidin amplification procedure with phycoerythrin as the fluorescent label. Microsphere-associated fluorescence was q...
متن کاملSerum copper is decreased in premature newborns and increased in newborns with hemolytic jaundice.
with the individual protein testing capacity of the WB. The assay can be tailored to the requirements of screening or confirmatory testing as well as to the needs of specific vaccine studies. Vaccine trials could benefit greatly from a PBA that differentiates protected from infected individuals. Because large-scale vaccine studies are likely to be conducted in settings where conditions may not ...
متن کاملHeterophile antibody interference in a multiplexed fluorescent microsphere immunoassay for quantitation of cytokines in human serum.
While modern immunoassays provide sensitive and specific means for the quantitation of cytokines in biological fluids, heterophile antibodies are still a well-recognized cause of interference in the measurement of cytokines in these assays. We have developed a multiplexed fluorescent microsphere immunoassay for the simultaneous quantification of 10 cytokines in only 75 microl of serum. During t...
متن کاملMultiplex Detection of Plant Pathogens Using a Microsphere Immunoassay Technology
Plant pathogens are a serious problem for seed export, plant disease control and plant quarantine. Rapid and accurate screening tests are urgently required to protect and prevent plant diseases spreading worldwide. A novel multiplex detection method was developed based on microsphere immunoassays to simultaneously detect four important plant pathogens: a fruit blotch bacterium Acidovorax avenae...
متن کاملDifferentiation of classical swine fever virus infection from CP7_E2alf marker vaccination by a multiplex microsphere immunoassay.
Classical swine fever (CSF) is a highly contagious viral disease of pigs that has a tremendous socioeconomic impact. Vaccines are available for disease control. However, most industrialized countries are implementing stamping-out strategies to eliminate the disease and avoid trade restrictions. These restrictions can be avoided through the use of marker vaccines such as CP7_E2alf. Marker vaccin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BioTechniques
دوره 27 2 شماره
صفحات -
تاریخ انتشار 1999