Jet nebulizers versus pressurized metered dose inhalers with valved holding chambers: effects of the facemask on aerosol delivery.
نویسندگان
چکیده
The delivery of an aerosolized drug to a child is a complex process requiring an interaction between parent, child, and inhalation device. Recent studies have shown that the facemask can be a key factor affecting aerosol delivery, particularly the influence of leaks between the facemask and the face. To further quantify these effects and design around them, we have developed a bench model consisting of a breathing simulator, an inhaled mass filter, and a "pediatric face." This paper reviews the development of this model and details important decisions made in its configuration, particularly inhaled mass filter location (e.g., between device and facemask, or in mouth) and mouth diameter (4 or 18 mm). With the final design, we used the model to measure the impact of the "blow-by" technique on nebulizer inhaled mass. In a separate series of experiments, we studied the effects of a "crying" pediatric breathing pattern on inhaled mass for both nebulizers and pressurized metered dose inhalers with valved holding chambers (pMDI VHCs). Results indicated that the location of the inhaled mass filter was a critical factor in assessing aerosol delivery through facemasks and that the "mouth diameter" was not an important variable. Failure to locate the filter in the mouth behind the face, especially for jet nebulizers, failed to accurately measure effects of the facemask and significantly overestimated aerosol delivery. Blow-by results indicated that a 1-cm gap between the facemask and the face was not critical when using a front-loaded facemask. Finally, even with optimal design, the combination of an aerosol generator and facemask with a crying breathing pattern reduced the inhaled mass to 1% of the label dose.
منابع مشابه
Aerosol delivery devices in the treatment of asthma.
Nebulizers convert solutions or suspensions into aerosols with a particle size that can be inhaled into the lower respiratory tract. There are pneumatic jet nebulizers, ultrasonic nebulizers, and mesh nebulizers. Newer nebulizer designs are breath-enhanced, breath-actuated, or have aerosol-storage bags to minimize aerosol loss during exhalation. Nebulizers can be used with helium-oxygen mixture...
متن کاملEquivalence Evaluation of Valved Holding Chambers (VHCs) with Albuterol Pressurized Metered Dose Inhaler (pMDI)
Valved holding chambers (VHCs) are medical devices that are recommended by International Asthma and Chronic Obstructive Pulmonary Disease (COPD) Guidelines [1, 2] to be used with pressurized metered dose inhalers (pMDI) as a delivery system. VHCs are designed to improve medication delivery, reduce oropharyngeal deposition of medication by substantially changing the aerodynamic particle size dis...
متن کاملOronasal and Tracheostomy Delivery of Soft Mist and Pressurized Metered-Dose Inhalers With Valved Holding Chamber.
BACKGROUND Some pediatric tracheostomized patients who receive inhaled drugs undergo decannulation, and it is unknown whether the dose has to be adjusted. Pressurized metered-dose inhalers (pMDIs) and soft mist inhalers (SMIs) used with valved holding chambers (VHCs) made of non-electrostatic material are available. We hypothesized that using an SMI and changing the delivery route from tracheos...
متن کاملThe role of the MDI and DPI in pediatric patients: "Children are not just miniature adults".
Metered-dose inhalers (MDIs) and dry powder inhalers play an important role in the treatment of asthma in children of all ages. Yet these devices, which were originally developed for use in adults, interact differently with children. Through childhood there are progressive changes in pharmacokinetic handling and pharmacodynamic effects of inhaled antiasthmatic drugs, in the efficiency and distr...
متن کاملForce-dependent static dead space of face masks used with holding chambers.
BACKGROUND Pressurized metered-dose inhalers with valved holding chambers and masks are commonly used for aerosol delivery in children. Drug delivery can decrease when the dead-space volume (DSV) of the valved holding chamber is increased, but there are no published data evaluating force-dependent DSV among different masks. METHODS Seven masks were studied. Masks were sealed at the valved hol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine
دوره 20 Suppl 1 شماره
صفحات -
تاریخ انتشار 2007