Estimation of corneal endothelial pump function in long-term contact lens wearers.
نویسندگان
چکیده
PURPOSE To study the effects of long-term contact lens wear on morphologic and physiologic properties of corneal endothelial cells. METHODS The endothelial permeability to fluorescein and the rate of corneal deswelling from hypoxia-induced edema were measured in 20 long-term (mean, 17+/-9 years; range, 5-33 years) contact lens wearers and 20 age-matched control subjects. From these data, the relative endothelial pump rate in each subject was estimated, based on the pump-leak hypothesis of corneal hydration control. Corneal autofluorescence and the aqueous humor flow rate were determined by fluorescein fluorophotometry. Images of corneal endothelial cells were recorded by using specular microscopy, and morphologic indices (cell density, coefficient of variation of cell area, percentage of hexagonal cells, and skewness) were determined. RESULTS No statistically significant differences were found between the contact lens and control groups in endothelial permeability, corneal deswelling, relative endothelial pump rate ([mean +/- SD] 1.07+/-0.33 relative pump units versus 1.01+/-0.25 relative pump units; contact lens versus control; P = 0.57), and endothelial cell density. Contact lens wearers had a significantly higher aqueous humor flow rate (3.57+/-1.03 microl/min versus 2.77+/-0.51 microl/min; P = 0.005), coefficient of variation of cell area (0.35+/-0.09 versus 0.28+/-0.04; P = 0.006), and corneal autofluorescence (3.1+/-0.6 ng/ml versus 2.3+/-0.3 ng/ml fluorescein equivalents; P < 0.001) than did non-contact lens wearers. CONCLUSIONS Despite the known effects of long-term contact lens wear on corneal endothelial morphometry, no effect on endothelial function was found.
منابع مشابه
Effect of long-term contact lens wear on corneal endothelial cell morphology and function.
Anterior segment fluorophotometry (topical) and central endothelial cell photography were performed on 40 long-term (2-23 years) contact lens wearers (four groups of ten each: hard, soft, gas permeable, and gas permeable plus prior lens usage) and 40 non-contact lens wearers of similar ages. Morphologically, the endothelial cells of contact lens wearers showed greater variability in size and sh...
متن کاملMorphology and function of the corneal endothelium after long-term contact lens wear.
PURPOSE To examine whether corneal hydration control is impaired in corneas with endothelial morphologic changes (increased variation in cell size and cell angularity) due to long-term low gas-permeable contact lens wear. METHODS Twenty-one long-term wearers of low gas-permeable contact lenses (mean age, 41 years +/- 8 SD) and 18 age-matched controls (mean age, 42 years +/- 8 SD) were studied...
متن کاملCorneal endothelial polymegathism induced by PMMA contact lens wear.
Central corneal endothelial photographs were taken for 15 persons who had worn polymethylmethacrylate (PMMA) contact lenses for 7-15 yr and for a nonwearing control group matched for age and sex. An individual cell area analysis was made from the cell tracings. Significant endothelial polymegathism was noted for each member of the contact lens wearing group. PMMA wearers showed an average coeff...
متن کاملDry eye in contact lens wearers as a growing public health problem.
BACKGROUND The aim of this study is to analyze the relationship between the self-reported symptoms and objective signs of dry eye disease in long-term rigid gas-permeable (RGP) or soft contact lens (SCL) wearers. SUBJECTS AND METHODS The study included 84 eyes of Caucasian RGP and SCL wearers between the age of 15 and 71 who wore contact lenses on a continuous daily basis for more than 1 year...
متن کاملCorneal and conjunctival sensory function: the impact on ocular surface sensitivity of change from low to high oxygen transmissibility contact lenses.
PURPOSE Deprivation of oxygen to the ocular surface during contact lens wear has been implicated in the alteration of sensory function. This study investigates whether increasing oxygen availability through discontinuation of contact lens wear or transfer into highly oxygen transmissible (high Dk/t) lenses leads to a change in corneal or conjunctival sensitivity. METHODS Twenty-seven long-ter...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 40 3 شماره
صفحات -
تاریخ انتشار 1999