Bi-functionalization of a patterned Prussian blue array for amperometric measurement of glucose via two integrated detection schemes.
نویسندگان
چکیده
A novel amperometric sensor that integrates two independent measurement schemes into a single chip for detection of glucose is fabricated. The sensor uses micro-patterned Prussian blue (PB) and ferrocene modified glucose oxidase covered by a thin Nafion membrane. We have developed an amperometric sensor for the detection of glucose that integrates two measurement schemes into a single chip. For fabrication of the sensing interface, micro-contact printing was used to transfer a self-assembled monolayer template onto a gold substrate, allowing selective electrochemical deposition of a PB array. The protective layer of the PB array was subsequently removed and replaced with a layer of redox-functionalized glucose oxidase (GOx), while the entire surface was finally covered with a perm-selective GOx-Nafion membrane. A variety of surface analytical techniques, including atomic force microscopy, surface plasmon resonance imaging and spectroscopic ellipsometry were employed to characterize the composite PB array electrode. The hybrid sensing interface allowed amperometric measurements of glucose to be carried out with two independent schemes at different potentials. The cathodic current was obtained with the PB array functioning as the electrocatalyst, while the anodic current was measured at a higher potential via a mediation mechanism using the ferrocene-modified GOx. For the quantitative detection of glucose, flow-injection analysis was used, and both the operating conditions and the design parameters were optimized. Linear responses were obtained for both anodic and cathodic signals over a concentration range from 0.1 to 50 mM, with a detection limit of 75 microM. The specificity of the sensor was demonstrated with respect to ascorbic and lactic acid. The implementation of integrated detection mechanisms allows the independent measurement of amperometric signals at two separate potentials. This improves the information gathering and opens up new avenues for developing novel methods that potentially eliminate false signal readings.
منابع مشابه
Amperometric Biosensor based on Prussian Blue Nanoparticle-modified
25 26 Glucose-6-phosphate (G6P) plays an important role in carbohydrate metabolism of all living 27 organisms. Compared to the conventional analytical methods available for estimation of G6P, the 28 biosensors having relative simplicity, specificity, low-cost and fast response time are a promising 29 alternative. We have reported a G6P biosensor based on screen-printed electrode utilizing 30 Pr...
متن کاملFunctionalized single-walled carbon nanotubes/polypyrrole composites for amperometric glucose biosensors
This article reports an amperometric glucose biosensor based on a new type of nanocomposite of polypyrrole (PPY) with p-phenyl sulfonate-functionalized single-walled carbon nanotubes (SWCNTs-PhSO3-). An environmentally friendly functionalization procedure of the SWCNTs in the presence of substituted aniline and an oxidative species was adopted. The nanocomposite-modified electrode exhibited exc...
متن کاملDevelopment of Amperometric Glucose Biosensor Based on Prussian Blue Functionlized TiO2 Nanotube Arrays
Amperometric biosensors consisting of oxidase and peroxidase have attracted great attention because of their wide application. The current work demonstrates a novel approach to construct an enzymatic biosensor based on TiO2 nanotube arrays (TiNTs) as a supporting electrode on which Prussian Blue (PB)-an "artificial enzyme peroxidase" and enzyme glucose oxidase (GOx) have been immobilized. For t...
متن کاملAn amperometric glucose biosensor based on titania sol-gel/Prussian Blue composite film.
An improved amperometric glucose biosensor was constructed by immobilizing glucose oxidase (GOD) in a titania sol-gel film, which was prepared by a vapor deposition method, on a Prussian Blue (PB)-modified electrode. The method combined the merits of immobilizing biomolecules in the titania sol-gel film by vapor deposition method and the synergic catalysis effects of PB and GOD molecules. Resul...
متن کاملPlanar Amperometric Glucose Sensor Based on Glucose Oxidase Immobilized by Chitosan Film on Prussian Blue Layer
A planar amperometric glucose microsensor based on glucose oxidase immobilized by chitosan film on Prussian Blue layer has been developed. The experimental results show that the optimum detection potential is 50 mV (versus Ag/AgCl) and the optimum pH is 6.5. Under the selective conditions the sensor exhibits excellent sensitivity of 98 nA/M and a linear range of 0.1-6.0 mM. The apparent Michane...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Analyst
دوره 132 2 شماره
صفحات -
تاریخ انتشار 2007