Ascorbic acid determination with an automated enzymatic procedure.

نویسندگان

  • W Lee
  • S M Roberts
  • R F Labbe
چکیده

Given the widespread interest in antioxidant nutrients, we have developed a new procedure that will permit the automated determination of plasma ascorbic acid (AA) concentration with a Roche Fara centrifugal analyzer. After the deproteinization of plasma with metaphosphoric acid, AA is oxidized to dehydroascorbic acid by AA oxidase. The product is coupled to o-phenylenediamine to produce a chromophore for which the absorbance is measured at 340 nm. The procedure allows much faster throughput than conventional HPLC methods while yielding results that correlate well and provide improved precision. Linearity extends beyond the reference range of 26.1-84.6 micromol/L, and severe hemolysis is the only interference identified.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A simple and rapid method for the routine assay of total ascorbic acid in serum and plasma using ascorbate oxidase and o-phenylenediamine.

A simple and rapid analysis of total ascorbic acid (AsA) in serum and plasma and its automated analysis are described. AsA is oxidized by ascorbate oxidase (AsA oxidase) to dehydroascorbic acid that then reacts with o-phenylenediamine (OPDA) to form a quinoxaline derivative that absorbs at 340 nm. The change in absorbance is directly proportional to the total AsA concentration. The assay was va...

متن کامل

Indirect Determination of Ascorbic Acid by Atomic Absorption Spectroscopy

A new and simple method followed by atomic absorption spectrometry has been developedfor indirect determination of ascorbic acid (AA). The proposed method was based on the oxidationof AA to dehydroascorbic acid with Cu2+cation(200mgL-1)in an ammonium thiocyanatesolution atpH2.4. AA reduces Cu2+to Cu+followed by the precipitation of Cu+ with SCN-. Then, the excess ofCu2+in the solution was measu...

متن کامل

Evaluation of an automated glucose-oxidase procedure.

We evaluated a slight modification of the automated oxidase/peroxidase method for glucose determination in blood with use of 4-aminophenazone [J. Clin. Pathol. 22, 246 (1969)]. Nonsugar reducing substances did not interfere, except for ascorbic acid in very high concentrations. Lipemic sera gave slightly lower values. Values for reproducibility, specificity, and sensitivity were closer to such ...

متن کامل

Detection of Ascorbic Acid in Biological Samples by a New Modified Glassy Carbon Electrode

The present work describes the construction of a new modified electrode by casting the appropriate mixture of a metallocene, which has been introduced in the experimental part, as a mediator at the surface of glassy carbon (GC) electrode. The proposed modified GC electrode was used for the determination of ascorbic acid (AA) in phosphate buffer (PB) solution (pH = 4.0). When compared to bare GC...

متن کامل

Determination of L- Ascorbic Acid in Plasma by Voltammetric Method

Voltammetric techniques have been considered as important methods among the analytical techniques used for the identification and determination of trace concentrations of many biological molecules such as L-ascorbic acid (AA). L-ascorbic acid is an electro-active molecule, though it is difficult to determine its value directly with a majority of electrodes made of carbon and transition metals, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 43 1  شماره 

صفحات  -

تاریخ انتشار 1997