Nitrogen Gas: A Possible Contraindication In Bubble Oxygenators

نویسنده

  • J. P. Mandl
چکیده

An ultrasonic Doppler was used to monitor embolic activity in the arterial line of an extracorporeal circuit. No differences in embolic activity were observed when either 100% N2 or 95% Oz-5% C02 gases were swept through a bubble oxygenator. Information is presented suggesting that nitrogen or air micro emboli are more deleterious than oxygen or carbogen microemboli. Consequently, this article recommends that the use of compressed air or nitrogen should be contraindicated in bubble oxygenators. Since the cardiotomy suction is a major source of nitrogen microemboli, this article also emphasizes that the cardiotomy suction be minimized and that a pressurized cardiotomy return be prevented from directly entering the oxygenator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gaseous micro emboli: concepts and considerations.

The production of gaseous micro emboli associated with bubble oxygenators during extracorporeal perfusion has prompted considerable attention regarding product design and arterial filtration needs. There are a variety of routes by which gas bubbles are introduced into the vasculature. As invasive diagnostics and extracorporeal perfusion are used more widely, likewise, the incidence of gas embol...

متن کامل

Oxygen or nitrogen: which is the lesser of two evils?

Ever since it was discovered in the 1770s, the risks and benefits of oxygen have been hotly debated (1). The article by Young, “Hyperoxia—A Review of Risk and Benefits,” the author addresses this important question: What is the optimal oxygen management strategy for cardiopulmonary bypass (CPB)? Surprisingly, after 60 years of clinical experience, there is still disagreement on the optimal part...

متن کامل

An in vitro method to quantitate gaseous microemboli production of bubble oxygenators. 1982.

____________ _ An in vitro method to collect and quantify volumes of gaseous microemboli generated by a bubble oxygenator has been developed. Gaseous microemboli generated by a bubble oxygenator are captured and collected in a vortex separation test cell. The cells are pressurized and the resultant pressure changes are converted to volume gas readings using a standard calibration curve. A doppl...

متن کامل

The transition from the bubble oxygenator to the microporous membrane oxygenator.

The transition from bubble oxygenators to microporous membrane oxygenators is a good example of how industry working with customers and material suppliers can help improve a surgical technique, such as cardiopulmonary bypass. The development is characterized by many individuals who, through their inventiveness and determination, made the transition possible. While the medical personnel involved...

متن کامل

A Simplified In Vitro System for Evaluating Gas Transfer Characteristics of Oxygenators

Despite the excellent performance of membrane oxygenators, bubble oxygenators continue to dominate routine open heart surgery. Newer versions with reduced gas:blood flow ratios continue to appear for clinical application 1•2. The new models generally provide data on partial pressure of oxygen (p02) of oxygenated blood at given blood and oxygen flow rates from clinical perfusions37. Clinical dat...