Thermal responses of ex vivo human skin during multiple cryogen spurts and 1,450 nm laser pulses.

نویسندگان

  • Rong Zhang
  • Julio C Ramirez-San-Juan
  • Bernard Choi
  • Wangcun Jia
  • Guillermo Aguilar
  • Kristen M Kelly
  • J Stuart Nelson
چکیده

BACKGROUND AND OBJECTIVE Although cryogen spray cooling (CSC) is used to minimize the risk of epidermal damage during laser dermatologic surgery, concern has been expressed that CSC may induce cryo-injury. The objective of this study is to measure temperature variations at the epidermal-dermal junction in ex vivo human skin during three clinically relevant multiple cryogen spurt-laser pulse sequences (MCS-LPS). STUDY DESIGN/MATERIALS AND METHODS The epidermis of ex vivo human skin was separated from the dermis and a thin-foil thermocouple (13 microm thickness) was inserted between the two layers. Thermocouple depth and epidermal thickness were measured using optical coherence tomography (OCT). Skin specimens were preheated to 30 degrees C before the MCS-LPS were initiated. Three MCS-LPS patterns, with total cryogen spray times of 38, 30, and 25 milliseconds respectively, were applied to the specimens in combination with laser fluences of 10 and 14 J/cm(2), while the thermocouple recorded the temperature changes at the epidermal-dermal junction. RESULTS The thermocouple effectively recorded fast temperature changes during three MCS-LPS patterns. The lowest temperatures measured corresponded to the sequences with longer pre-cooling cryogen spurts. No sub-zero temperatures were measured for any of the MCS-LPS patterns under study. CONCLUSIONS The three clinically relevant MCS-LPS patterns evaluated in this study do not cause sub-zero temperatures in ex vivo human skin at the epidermal-dermal junction and, therefore, are unlikely to cause significant cryogen induced epidermal injury.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cryogen spray cooling efficiency: improvement of port wine stain laser therapy through multiple-intermittent cryogen spurts and laser pulses.

BACKGROUND AND OBJECTIVES Cryogen spray cooling (CSC) is used to minimize the risk of epidermal damage during laser treatment of port wine stain (PWS) birthmarks. Unfortunately, CSC may not provide the necessary protection for patients with high concentrations of epidermal melanin. The objectives of this study are to: (1) provide a definition of cooling efficiency (eta) based on the amount of h...

متن کامل

Heat Transfer Dynamics during Treatment of Port Wine Stain Birthmarks with Multiple-intermittent Cryogen Spurts and Laser Pulses

Port wine stain (PWS) is a congenital, progressive vascular malformation of human skin. Presently, all PWS patients are treated using single cryogen spurt and single laser pulse exposure (SCS-SLP), which does not produce complete lesion blanching in the vast majority of patients. In this study, the feasibility of applying multiple cryogen spurts intermittently with multiple laser pulse exposure...

متن کامل

Experimental study of multiple-intermittent cryogen spurts and laser pulses for the treatment of port wine stain birthmarks

Cryogen spray cooling (CSC) is used to minimize the risk of epidermal damage during pulsed laser treatment of port wine stain (PWS) birthmarks. Unfortunately, the current approach to CSC does not provide the necessary epidermal protection for all patients, particularly those with darker skin types. Therefore, alternative approaches need to be sought to improve PWS laser therapy. On a previous n...

متن کامل

Treatment of cutaneous vascular lesions using multiple-intermittent cryogen spurts and two-wavelength laser pulses: numerical and animal studies.

BACKGROUND AND OBJECTIVES Presently, cutaneous vascular lesions are treated using a single cryogen spurt and single laser pulse (SCS-SLP), which do not necessarily produce complete lesion removal in the majority of patients. In this study, the feasibility of applying multiple cryogen spurts intermittently with multiple two-wavelength laser pulses (MCS-MTWLP) was studied using numerical and anim...

متن کامل

Measurements of laser light attenuation following cryogen spray cooling spurt termination.

BACKGROUND AND OBJECTIVES Cryogen spray cooling (CSC) is used to minimize the risk of epidermal damage during laser dermatological surgery. However, while CSC can protect the epidermis from non-specific thermal damage, the cryogen film on the skin surface may pose a potential problem of laser light attenuation due to optical scattering. STUDY DESIGN/MATERIALS AND METHODS This study is focused...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lasers in surgery and medicine

دوره 38 2  شماره 

صفحات  -

تاریخ انتشار 2006