Defining left ventricular apex-to-base twist mechanics computed from high-resolution 3D echocardiography: validation against sonomicrometry.

نویسندگان

  • Muhammad Ashraf
  • Andriy Myronenko
  • Thuan Nguyen
  • Akio Inage
  • Wayne Smith
  • Robert I Lowe
  • Karl Thiele
  • Carol A Gibbons Kroeker
  • John V Tyberg
  • Jeffrey F Smallhorn
  • David J Sahn
  • Xubo Song
چکیده

OBJECTIVES To compute left ventricular (LV) twist from 3-dimensional (3D) echocardiography. BACKGROUND LV twist is a sensitive index of cardiac performance. Conventional 2-dimensional based methods of computing LV twist are cumbersome and subject to errors. METHODS We studied 10 adult open-chest pigs. The pre-load to the heart was altered by temporary controlled occlusion of the inferior vena cava, and myocardial ischemia was produced by ligating the left anterior descending coronary artery. Full-volume 3D loops were reconstructed by stitching of pyramidal volumes acquired from 7 consecutive heart beats with electrocardiography gating on a Philips IE33 system (Philips Medical Systems, Andover, Massachusetts) at baseline and other steady states. Polar coordinate data of the 3D images were entered into an envelope detection program implemented in MatLab (The MathWorks, Inc., Natick, Massachusetts), and speckle motion was tracked using nonrigid image registration with spline-based transformation parameterization. The 3D displacement field was obtained, and rotation at apical and basal planes was computed. LV twist was derived as the net difference of apical and basal rotation. Sonomicrometry data of cardiac motion were also acquired from crystals anchored to epicardium in apical and basal planes at all states. RESULTS The 3D dense tracking slightly overestimated the LV twist, but detected changes in LV twist at different states and showed good correlation (r = 0.89) when compared with sonomicrometry-derived twist at all steady states. In open chest pigs, peak cardiac twist was increased with reduction of pre-load from inferior vena cava occlusion from 6.25 degrees +/- 1.65 degrees to 9.45 degrees +/- 1.95 degrees . With myocardial ischemia from left anterior descending coronary artery ligation, twist was decreased to 4.90 degrees +/- 0.85 degrees (r = 0.8759). CONCLUSIONS Despite lower spatiotemporal resolution of 3D echocardiography, LV twist and torsion can be computed accurately.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sex-related Left Ventricle Rotational and Torsional Mechanics by Block Matching Algorithm

Background: The aim of the present study was to evaluate how left ventricular twist and torsion are associated with sex between sex groups of the same age.Materials and Methods: In this analytical study, twenty one healthy subjects were scanned in left ventricle basal and apical short axis views to run the block matching algorithm; instantaneous changes in the base and apex rotation angel...

متن کامل

Myocardial strain by Doppler echocardiography. Validation of a new method to quantify regional myocardial function.

BACKGROUND Myocardial strain is a measure of regional deformation, and by definition, negative strain means shortening and positive strain, elongation. This study investigates whether myocardial strain can be measured by Doppler echocardiography as the time integral of regional velocity gradients, using sonomicrometry as reference method. METHODS AND RESULTS In 13 anesthetized dogs, myocardia...

متن کامل

Importance of preserving the apex and plication of the base in left ventricular volume reduction surgery.

OBJECTIVE Volume reduction surgery for dilated cardiomyopathy has not yielded predictable outcomes. The purpose of this study was to clarify the efficacy of modified volume reduction surgery in preserving the left ventricular apex and reducing the left ventricular diameter at the base to maintain fiber continuity. METHODS Heart failure was induced with propranolol in 12 dogs, and the animals ...

متن کامل

Left ventricular strain distribution in healthy dogs and in dogs with tachycardia-induced dilated cardiomyopathy

BACKGROUND Recently, left ventricular (LV) strain distribution pattern has been assessed in several cardiac disease states. Tachycardia-induced cardiomyopathy (TIC) is an animal model of non-ischemic cardiomyopathy well characterized in terms of global LV dysfunction but with poor understanding of regional variability in LV function. We hypothesized that TIC induces specific changes in LV strai...

متن کامل

Integrated Ventricular Mechanics in “Healthy” Heart Transplant Patients

Although recently studies using Speckle Tracking Echocardiography (STE) on heart transplant (HTX) recipients have been published, an integrated assessment of myocardial properties is lacking. Thus our aim was to perform, by STE, an integrated study of ventricular mechanics in “healthy” HTX recipients. Standard echo-Doppler and STE study were performed in 50 HTX patients (age 50.4 ± 7.8, M/F = 3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular imaging

دوره 3 3  شماره 

صفحات  -

تاریخ انتشار 2010