Tolerability to high doses of formoterol and terbutaline via Turbuhaler for 3 days in stable asthmatic patients.
نویسندگان
چکیده
This randomized, double-blind, crossover study in two parts compared tolerability to high doses of formoterol (Oxis Turbuhaler) with that of high doses of terbutaline (Bricanyl Turbuhaler). After Holter monitoring at home, 12 patients were treated with 4+4+4 doses of formoterol Turbuhaler, 6 microg x dose(-1), (total daily metered dose 72 microg) or 4+4+4 doses of terbutaline Turbuhaler, 0.5 mg x dose(-1) (daily dose 6 mg) given in the morning, after lunch and in the evening, for 3 consecutive days. After a one week washout period at home, patients received the alternative treatment. Thereafter, 15 other patients received 8+6+6 doses of formoterol Turbuhaler (total daily metered dose 120 microg) or 8+6+6 doses of terbutaline Turbuhaler (daily dose 10 mg). Pulse, cardiac frequency, blood pressure, serum potassium, electrocardiogram and forced expiratory volume in one second (FEV1) were registered at regular intervals and Holter monitoring was applied during all 4 treatment days. Terbutaline 6 mg showed significantly greater systemic effects than formoterol 72 microg on pulse, blood pressure, cardiac frequency and QTc (QT interval corrected for heart rate). Terbutaline 10 mg had significantly greater effects than formoterol 120 microg on serum potassium levels, pulse, cardiac frequency and QTc. No differences in FEV1 levels were found. Both drugs were safe and generally well tolerated on both dose levels. In conclusion, high doses of formoterol Turbuhaler over 3 days were generally safe and well tolerated. Daily doses of 6 mg and 10 mg terbutaline Turbuhaler were systemically more potent than 72 microg and 120 microg formoterol, respectively. The safety margin thus appears to be wide if patients happen to use extra doses of formoterol in addition to those prescribed for regular use.
منابع مشابه
Terbutaline via pressurised metered dose inhaled (P-MDI) and Turbuhaler in highly reactive asthmatic patients.
There is some concern over the environmental consequences of chlorofluorocarbons (CFCs) used in pressurized metered-dose inhalers (p-MDIs). Turbuhaler was designed to deliver a drug as a dry powder without administering additives directly to the airways. The aim of this study was to evaluate the comparative irritant and bronchodilating effects of the same dose of terbutaline delivered by a p-MD...
متن کاملAcute protection against exercise-induced bronchoconstriction by formoterol, salmeterol and terbutaline.
The onset of bronchoprotection as obtained by various beta2-agonists has not been examined in a comparitive study. In this study, the onset of bronchodilation and protection against exercise-induced bronchoconstriction in asthmatics after inhalation of the long-acting beta2-agonists formoterol and salmeterol and the short-acting beta2-agonist terbutaline were measured. Twenty-five subjects with...
متن کاملDose-related effects of formoterol on airway responsiveness to adenosine 5'-monophosphate and histamine.
Inhaled short-acting beta2-agonists provide greater protection against airway responsiveness (AR) to the mast-cell stimulus, adenosine 5'-monophosphate (AMP), than to histamine, a direct spasmogen. Both terbutaline and albuterol exhibit this mast-cell stabilizing property in a dose-dependent manner. A single dose of the long-acting beta2-agonist formoterol has also been reported to have a mast ...
متن کاملA new multiple dose powder inhaler, (Turbuhaler), compared with a pressurized inhaler in a study of terbutaline in asthmatics.
Twelve adult asthmatic patients participated in an open, randomized, cross-over comparison between cumulatively increasing doses of terbutaline sulphate administered via the multiple dose powder inhaler (Turbuhaler) or via a pressurized inhaler. Turbuhaler and the pressurized inhaler showed equipotency both with respect to bronchodilatation and side effects. Both treatments produced a significa...
متن کاملEffects of formoterol in apparently poorly reversible chronic obstructive pulmonary disease.
This randomized, double-blind, placebo-controlled, crossover study was designed to investigate the effects of the long-acting beta2-adrenoreceptor agonist formoterol fumarate in 12 current or exsmokers having chronic obstructive pulmonary disease, with a mean forced expiratory volume in one second (FEV1) 47% of predicted, poorly reversible (5.1% pred) after terbutaline sulphate inhalation. Afte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 12 3 شماره
صفحات -
تاریخ انتشار 1998