Estimating amounts of iron oxide from gradient echo images.

نویسندگان

  • W Thomas Dixon
  • Daniel J Blezek
  • Lisa A Lowery
  • Dan E Meyer
  • Amit M Kulkarni
  • Brian C Bales
  • Danielle L Petko
  • Thomas K Foo
چکیده

Rat legs directly injected with superparamagnetic iron oxide (SPIO) were studied by dual-echo, gradient-echo imaging. The amount of iron injected was estimated using a point dipole model for the SPIO injection site. Saturation magnetization of 6:1 PEG/amino modified silane-coated iron oxide particles with 5- to 6-nm core and 20-25 hydrodynamic diameter was approximately 110 emu/g of iron. Estimates of the amount of iron injected made from signal void volumes surrounding SPIO centers yielded erroneous results varying with sample orientation in the scanner and echo time (TE). For example, a 10 microL, 3-microg iron injection produced signal void volumes of 80 and 210 microL at TE of 9.8 and 25 ms, respectively, giving apparent iron contents of 6 +/- 1 and 10 +/- 2 microg respectively. A more effective approach uses the phase difference between two gradient recalled echo images. To estimate iron content, this approach fits the expected (3 cos(2)theta - 1)/(/r/3) spatial phase distribution to the observed phase differences. Extraneous phase effects made fitting phase at a single TE ineffective. With the dual echo method, 18 independent estimates were 2.48 +/- 0.26 microg std, independently of sample orientation. Estimates in empty control regions were -90 and -140 ng. A 1-microg injection indicated 0.5, 1.2, and 1.2 microg.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dextran-coated superparamagnetic iron oxide, an MR contrast agent for assessing lymph nodes in the head and neck.

PURPOSE To investigate dextran-coated superparamagnetic iron oxide particles (BMS 180549) as an MR contrast agent for assessing lymph nodes. METHODS Five different doses ranging from 0.3 to 1.7 mg Fe/kg were evaluated in five healthy human male subjects as part of a phase 1 clinical study. T1-, T2-, and proton density-weighted spin-echo images as well as multiplanar gradient-echo and spoiled ...

متن کامل

In-vivo Visualization of Iron Oxide Enhancement in Focal Pulmonary Inflammatory Lesions Using a Three-Dimensional Radial Gradient-Echo-Based Ultrashort Echo Time Sequence: A Preliminary Study

Objective To preliminarily evaluate technical feasibility of a dual-echo ultrashort echo time (UTE) subtraction MR imaging by using concurrent dephasing and excitation (CODE) sequence for visualization of iron-oxide enhancement in focal inflammatory pulmonary lesions. Materials and Methods A UTE pulmonary MR imaging before and after the injection of clinically usable superparamagnetic iron-ox...

متن کامل

ANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST

Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...

متن کامل

Relaxometry vs artefact volume measurements for estimating the number of iron-labelled macrophages: in vivo testing in the mouse brain

Rationales and objectives: In recent years, numerous studies have been published on the use of iron oxide nanoparticles for MRI assessment of macrophage infiltration in neuroinflammatory diseases [1]. Quantitative estimate of iron-labelled cells is highly desirable in such studies, as it could allow to monitor the effects of anti-inflammatory drugs. In-vitro studies performed at 4.7T [2] have s...

متن کامل

Comparison of two superparamagnetic viral-sized iron oxide particles ferumoxides and ferumoxtran-10 with a gadolinium chelate in imaging intracranial tumors.

BACKGROUND AND PURPOSE Ultrasmall superparamagnetic iron oxide particles result in shortening of T1 and T2 relaxation time constants and can be used as MR contrast agents. We tested four hypotheses by evaluating MR images of intracranial tumors after infusion of two iron oxide agents in comparison with a gadolinium chelate: 1) Ferumoxtran in contrast to ferumoxides can be used as an intravenous...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 61 5  شماره 

صفحات  -

تاریخ انتشار 2009