Automated determination of acid phosphatase. II. Technic for using robot chemist.

نویسندگان

  • B Klein
  • M Oklander
  • S Morgenstern
چکیده

A procedure is presented for the automated determination of acid phosphatase activity in biological materials using the Robot Chemist. Although either phenylphosphate and a-naphthylphosphate may be used as substrate in this analysis, the procedure is described in detail for serum acid phosphatase using a-naphthylphosphate in 0.1 M citrate, pH 5.2, since this substrate is more selective for prostatic acid phosphatase in human serum. Enzymically generated a-naphthol is determined by the Emerson reaction (alkaline aminoantipyrine and ferricyanide), modified for use with this automated system. Correlations are presented between the results obtained on the Robot Chemist and the identical procedure developed for the AutoAnalyzer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An automated p-nitrophenylphosphate serum alkaline phosphatase procedure for the "Robot Chemist".

A new, precise, and accurate procedure is described for the automated determination of serum alkaline phosphatase on the Robot Chemist. The substrate, p-nitrophenylphosphate in 2-amino-2-methyl-1-propanol, offers the prime advantage of providing directly its own chromogen, p-nitrophenol, following enzyme action. Other advantages are the small sample volumes required and linear reaction rates. C...

متن کامل

The automated determination of NAD-coupled enzymes. II. Serum lactate dehydrogenase.

A precise automated procedure developed for determination of serum lactate dehydrogenase, using the Robot Chemist, measures absorbance of a cuprous-neocuproine complex formed by coupled reduction of the cupric-neocuproine reagent with enzymatically generated reduced nicotinamide adenine dinucleotide. Activity values obtained by this method, by the identical automated colorimetric method on the ...

متن کامل

The automated determination of serum uric acid.

An automated procedure is presented for the enzymatic determination of serum uric acid on both the AutoAnalyzer and the Robot Chemist. The procedure measures as the neocuproine complex, the difference in the amount of Cu+ formed by reaction of a Cu++ aIkanoIamine buffered solution with serum uric acid under precisely controlled conditions before and after uricase treatment of the serum. The dif...

متن کامل

P-10: Effects of Cadmium on Reproductive Enzymes of Blood and Reproductive Tissues in Adult Male Mice

Background: Heavy metals such as cadmium (Cd2+) are natural components of the Earth's crust which can not be degraded or destroyed. Industrial, mining and agricultural activities, particularly the excessive use of phosphate fertilizers, have led to high levels of cadmium contamination at many locations worldwide. Some toxic effects of cadmium are due to its inhibition of various enzyme sys...

متن کامل

DETERMINATION OF ULTRA-TRACE AMOUNTS OF COBALT BY ADSORPTIVE DIFFERENTIAL PULSE VOLTAMMETRY USING ACDA (2-AMINOCYCLOPENTENE- 1-DITHIOCARBOXYLIC ACID)

The present work describes a selective, rapid and sensitive method for the determination of cobalt using the adsorptive differential pulse voltammetry technique. The method is based on the accumulation of Co(II) complex with 2-aminocyclopentene-1-dithiocarboxylic acid on a hanging mercury drop electrode, followed by measurement of the current of the adsorbed complex. The effects of experimental...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 12 4  شماره 

صفحات  -

تاریخ انتشار 1966