Long-term results of aortic valve replacement with mechanical prosthesis or carpentier-edwards perimount bioprosthesis in Japanese patients according to age.

نویسندگان

  • Takahiro Nishida
  • Hiromichi Sonoda
  • Yasuhisa Oishi
  • Hideki Tatewaki
  • Yoshihisa Tanoue
  • Yuichi Shiokawa
  • Ryuji Tominaga
چکیده

BACKGROUND The long-term results of aortic valve replacement (AVR; n=737) with bileaflet mechanical prosthesis (MP) or Carpentier-Edwards Perimount bioprostheses (BP) were evaluated in different age groups. METHODS AND RESULTS: Since 1981, a total of 737 prostheses (424 bileaflet MP vs. 313 BP) were implanted for AVR in 278 patients aged ≥70 years (79 MP vs. 199 BP), in 191 patients aged 60-69 years (128 MP vs. 63 BP) and in 268 patients aged <60 years (217 MP vs. 51 BP). Follow-up was completed for 6,523 patient-years in 98.5% of cases. Among the patients ≥70 years, both the actuarial survival rate (P=0.0434) and freedom from valve-related morbidity (P=0.0205) were better in the BP group than in the MP group without any difference in occurrence of structural valve deterioration in both groups. Among the patients aged 60-69, anticoagulant-related complications occurred less often in the BP group (P=0.0134) without any difference in long-term survival. Among the patients aged <60, long-term survival was significantly better in the MP group, whereas freedom from anticoagulant-related events did not differ. CONCLUSIONS The use of BP is suitable in patients aged ≥70 years, while the use of bileaflet MP is preferable in patients aged <60 years. Among patients aged 60-69 years, the use of BP is acceptable because of the lower incidence of anticoagulant-related events and the equivalent long-term survival.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Very long-term outcomes of the Carpentier-Edwards Perimount valve in aortic position.

BACKGROUND The Carpentier-Edwards Perimount pericardial bioprosthesis (Edwards Lifesciences, Irvine, CA) has demonstrated good long-term outcomes, but its durability remains unclear depending on age at implantation. We report our 20-year experience with the Perimount valve implanted in the aortic position, with particular attention to the probability and time to reoperation required due to biop...

متن کامل

Mechanical prosthesis is reasonable for mitral valve replacement in patients approximately 65 years of age.

BACKGROUND The long-term results of mitral valve replacement (MVR; n = 631) with a bileaflet mechanical prosthesis or a Carpentier-Edwards Perimount bioprosthesis were evaluated in Japanese patients of different age groups. METHODS A total of 507 bileaflet mechanical prostheses and 124 bioprostheses have been implanted since 1982 at our institution. Follow-up was completed for 6,598 patient-y...

متن کامل

Comparable long-term results for porcine and pericardial prostheses after isolated aortic valve replacement

OBJECTIVES Outcome of aortic valve replacement may be influenced by the choice of bioprosthesis. Pericardial heart valves are described to have a favourable haemodynamic profile compared with porcine valves, although the clinical notability of this finding is still controversially debated. Herein, we compared the long-term results of two commonly implanted bioprosthesis at a single centre. ME...

متن کامل

Long-term clinical and hemodynamic performance of the Hancock II versus the Perimount aortic bioprostheses.

BACKGROUND The Medtronic Hancock II and the Carpentier-Edwards Perimount are among the world's most commonly used aortic bioprostheses. However, a direct comparison of their clinical performance is lacking. To minimize biases inherent to between-center comparisons, we examined these prostheses within a large, contemporary, single-center cohort. METHODS AND RESULTS Between 1990 and 2007, 1659 ...

متن کامل

Exercise hemodynamics of bovine versus porcine bioprostheses: a prospective randomized comparison of the mosaic and perimount aortic valves.

OBJECTIVE This prospective randomized study compares a porcine with a bovine bioprosthesis in the aortic position with regard to hemodynamic performance during exercise. METHODS Between August of 2000 and December of 2002, 136 patients underwent aortic valve replacement with the porcine Medtronic Mosaic (n = 66) or the bovine Carpentier-Edwards Perimount (n = 70) bioprosthesis. Transthoracic ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 78 11  شماره 

صفحات  -

تاریخ انتشار 2014