Sonication of antibiotic-loaded cement spacers in a two-stage revision protocol for infected joint arthroplasty

نویسندگان

  • Massimo Mariconda
  • Tiziana Ascione
  • Giovanni Balato
  • Renato Rotondo
  • Francesco Smeraglia
  • Giovan Giuseppe Costa
  • Marco Conte
چکیده

BACKGROUND Culturing of the sonication fluid of removed implants has proven to be more sensitive than conventional periprosthetic tissue culture for the microbiological diagnosis of prosthetic joint infection. Since bacteria surviving on antibiotic-loaded cement spacers used in a two-stage exchange protocol for infected arthroplasties may cause the persistence of infection, in this study we asked whether the sonication also could be used to identify bacteria on antibiotic-loaded cement spacers removed at the second surgical stage during a two-stage exchange procedure to confirm whether or not the prosthetic joint infection had been eradicated. METHODS We cultured the sonication fluid of cement spacers that had been originally implanted in a two-stage exchange protocol in 21 patients (mean age, 66 years) affected by prosthetic joint infection (16 total knee prostheses and 5 hip prostheses). The cement spacers were vortexed for 30 seconds and then subjected to sonication (frequency 35-40 KHz). The resulting sonicate fluid was cultured for aerobic and anaerobic bacteria. RESULTS The sonication fluid culture of the removed spacer was positive in six patients (29%), with isolation of methicillin-sensible Staphylococcus Aureus (MSSA) in three cases, methicillin-resistant Staphylococcus Aureus (MRSA) in one case and Pseudomonas Aeruginosa in two cases. In three of these positive cases, the traditional culture of periprosthetic tissue was negative. Two patients with positive sonication culture of the spacer were successfully treated by early debridement of the revision prosthesis and systemic antibiotic therapy. In three patients a knee arthrodesis was planned and performed as the second surgical stage. In two of them the infection was caused by highly resistant Pseudomonas Aeruginosa. The other patient with a MSSA infection had been poorly compliant with the systemic antibiotic therapy due to her mental impairment. The patient originally affected by MRSA infection of his primary hip arthroplasty developed recurrent infection of his revision prosthesis and eventually underwent Girdlestone arthroplasty. CONCLUSIONS The sonication culture can be used to discover any bacteria on the antibiotic-loaded cement spacer during a two-stage exchange protocol, thus permitting the adoption of timely treatment options, such as the early prosthetic debridment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Use of Antibiotic Impregnated Cement Spacers in the Treatment of Infected Total Joint Replacement: Challenges and Achievements

Two stage total hip arthroplasty revision surgery includes foreign material debridment, insertion of antibiotic impregnatedcement spacer, and finally, reimplantation of the prosthesis. This review has aimed to evaluate the efficacy of antibioticimpregnated cement spacers in infection control and eradication in arthroplasties.A total of 85 articles on total hip arthroplasty wer...

متن کامل

Antibiotic-loaded bone cement in total joint arthroplasty.

Periprosthetic joint infection is a devastating complication after total joint replacement. Prevention is mandatory and systemic antibiotic prophylaxis is nowadays a recognized cornerstone. Further addition of local antibiotics eluting from bone cement is a real possibility but its routine use is controversial. Pros and cons of its routine use in primary and revision total joint arthroplasty wi...

متن کامل

Results of cement spacer sonication in the second stage of two-stage treatment of shoulder arthroplasty infection

BACKGROUND The objective of this study is to present the results of cement spacer sonication in the second stage of two-stage treatment of shoulder arthroplasty infection and to determine the rate of positive cultures in the second-stage surgery in shoulder arthroplasty and its meaning. METHODS Twenty-one patients (22 cement spacers) treated with two-stage surgery because of a shoulder arthro...

متن کامل

Two-stage exchange of infected knee arthroplasty with an prosthesis-like interim cement spacer.

Two-stage revision in infected knee arthroplasty is standard practice. One problem during the interim period is soft tissue fibrosis. Attempts have been made to preserve leg length and ligament length by introducing spacers, usually made out of antibiotic-loaded bone cement. We present a new interim prosthesis, which is made intra-operatively out of polymethylmethacrylate (PMMA). Antibiotic-loa...

متن کامل

Titanium-copper-nitride coated spacers for two-stage revision of infected total hip endoprostheses

Within the first two years after total hip arthroplasty implant-associated infection has become the second most common reason for a revision surgery. Two-stage implant exchange is frequently conducted using temporary spacers made of antibiotic-loaded cement in order to prevent a bacterial colonization on the spacer. Avoiding several disadvantages of cement spacers, a conventional hemi-endoprost...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013