Assessment of Fluid Shifts of Body Compartments using Both Bioimpedance Analysis and Blood Volume Monitoring
نویسندگان
چکیده
Fluid shifts are commonplace in chronic hemodialysis patients during the intra- and interdialytic periods. In this study, we evaluated fluid shifts of body compartments using both bioimpedance spectroscopy and blood volume monitoring from the start to the end of hemodialysis. 24 stable hemodialysis patients were included on the study. Relative change of blood volume was progressively reduced from the start to the end of hemodialysis (1 hr, -7.22+/-3.23%; 2 hr, -9.78+/-4.69%; 3 hr, -12.88+/-5.65%; 4 hr, -15.41+/-6.54%, respectively). Mean % reduction of intracellular fluid was not significantly different to that of extracellular fluid at the end of hemodialysis (delta ICF, -6.58+/-5.34% vs. delta ECF, -7.07+/-5.12%). Mean % fluid reduction of arms, legs and trunk was -11.98+/-6.76%, -6.43+/-4.37% and -7.47+/-4.56%, respectively at the end of hemodialysis. There were 3 characteristic patterns in blood-volume change. Similar amounts of fluid were removed from the extracellular and intracellular compartments during hemodialysis, with the arms showing the greatest loss in terms of body segments. The pattern of blood volume change measured by blood volume monitoring may be useful for more accurate determination of dry-weight and for correcting volume status in hemodialysis patients.
منابع مشابه
Bioimpedance Identifies Body Fluid Loss after Exercise in the Heat: A Pilot Study with Body Cooling
PURPOSE Assessment of post-exercise changes in hydration with bioimpedance (BI) is complicated by physiological adaptations that affect resistance (R) and reactance (Xc) values. This study investigated exercise-induced changes in R and Xc, independently and in bioelectrical impedance vector analysis, when factors such as increased skin temperature and blood flow and surface electrolyte accumula...
متن کاملBody fluid compartments in hypertension.
BACKGROUND AND OBJECTIVES There is a correlation between the fluid and ionic homeostasis and blood pressure but it is not known if these body fluid changes represent the cause or rather the effect of the blood pressure rise. We have estimated the compartmental distribution of body fluids by means of the Bioimpedance Spectroscopy (BIS) analysis in a hypertensive cohort compared to control subjec...
متن کاملAn objective measure for the assessment and management of fluid shifts in acute major burns
Background: Major burns are life threatening. Fluid resuscitation is required for survival to maintain intravascular volumes and prevent hypovolemic shock. Bioimpedance spectroscopy (BIS) has been recognised as a potential method of monitoring fluid shifts after burn and in other disease states. The aims of this study were to examine the reliability of BIS across different dressing conditions a...
متن کاملSensitivity of blood volume monitoring for fluid status assessment in hemodialysis patients.
BACKGROUND/AIMS This study investigates the use of blood volume monitoring (BVM) markers for the assessment of fluid status. METHODS Predialysis fluid overload (FO) and BVM data were collected in 55 chronic hemodialysis patients in 317 treatments. Predialysis FO was measured using bioimpedance spectroscopy. The slope of the intravascular volume decrease over time normalized by ultrafiltration...
متن کاملThe role of natriuretic peptides in volume assessment and mortality prediction in Haemodialysis patients.
BACKGROUND Maintaining optimal fluid balance is essential in haemodialysis (HD) patients but clinical evaluation remains problematic. Other technologies such as bioimpedance are emerging as valuable adjuncts. This study was undertaken to explore the potential utility of the natriuretic peptides - atrial natriuretic peptide (ANP) and B-type natriuretic peptide (BNP) in the assessment of fluid st...
متن کامل