Apparatus for the Measurement of the Normal Spectral Emissivity in the Infrared

نویسندگان

  • Arthur G. Maki
  • Ralph Stair
  • Russell G. Johnston
چکیده

The measuremen t of the spectral emlSSlVl ty of heated substances may be accomplished by comparing the energy emitted by the substance under study 'with that emitted by a standard substance for radiation at various wavelengths. For such a standard one usually uses a blackbody, that is, a hollow body provided with a hole for viewing the radia tion inside. The inside surface of the blackbody must be maintained at a uniform temperature. The wavelength separation may be accomplished using a double-beam monochromator or a singlebeam monochromator. Th e specimen under investigation may be formed in to a rod, bar, ribbon , or other shape. Some workers have even formed the specimen into a blackbody. For such a specimen both the in slde surface (the blackbody) and the outside surface (the specimen) are observed . The double-beam monochromator and associated method have certain advantages especially with relation to the elimination of the effects of absorption by carbon dioxide and water vapor, but the optical adjustment is critical as compared with a single-beam instrument. Furthermore through the use of a single se t of optics and equal path lengths in the single-beam monochromator the effects of both atmospheric absorption and differential reflectivity in the auxiliary optics are practically eliminated. The apparatus described herein is of the latter type. The specimen may vary in temperature from poin t to point depending upon its shape, size, and method of heating. If made into the form of a blackbody the inside temperature may dIffer from that on the outside. A convenient shape is that of a long thin ribbon heated electrically by contacts at the two ends. The data presented in this paper apply to samples of this type for which the temperature is measured by means of thermocouples in metallic contact with the opposite face from the pomt of radifint energy measurement. 2. Apparatus and Method

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fourier-Transform Infrared Spectroscopic Comparison of Normal and Malignant Cervical Tissue Cervical Tissue.

Based on the accumulated data, FTIR spectroscopy seems to be a highly sensitive tool in cervical cancer diagnosis. We, therefore, employed this technique in a screening type of research here in Tehran. The purpose of this study was to look for the spectral pattern differences between normal and malignant cervix samples in Iranian women. Through formal and informal announcements, all gynecology ...

متن کامل

Fourier-Transform Infrared Spectroscopic Comparison of Normal and Malignant Cervical Tissue Cervical Tissue.

Based on the accumulated data, FTIR spectroscopy seems to be a highly sensitive tool in cervical cancer diagnosis. We, therefore, employed this technique in a screening type of research here in Tehran. The purpose of this study was to look for the spectral pattern differences between normal and malignant cervix samples in Iranian women. Through formal and informal announcements, all gynecology ...

متن کامل

Non-Contact Measurement of the Spectral Emissivity through Active/Passive Synergy of CO2 Laser at 10.6 µm and 102F FTIR (Fourier Transform Infrared) Spectrometer

In the inversion of land surface temperature (LST) from satellite data, obtaining the information on land surface emissivity is most challenging. How to solve both the emissivity and the LST from the underdetermined equations for thermal infrared radiation is a hot research topic related to quantitative thermal infrared remote sensing. The academic research and practical applications based on t...

متن کامل

Technical guide to Set Up a Spectral Solar Direct Normal Irradiance Permanent Station: Study Area- Hannover, Germany

The spectral Direct Normal Irradiance (SDNI) is a basic radiometric quantity from which many other quantities can be derived. It provides not only information about the spectral and distribution of the direct solar radiation reaching a particular location. Accurate knowledge about the spectral direct irradiance shall enable us to gain new scientific results in the: determination of cloud effect...

متن کامل

Spatial-Spectral-Emissivity Land-Cover Classification Fusing Visible and Thermal Infrared Hyperspectral Imagery

High-resolution visible remote sensing imagery and thermal infrared hyperspectral imagery are potential data sources for land-cover classification. In this paper, in order to make full use of these two types of imagery, a spatial-spectral-emissivity land-cover classification method based on the fusion of visible and thermal infrared hyperspectral imagery is proposed, namely, SSECRF (spatial-spe...

متن کامل

Comparison of field and laboratory collected midwave and longwave infrared emissivity spectra / data reduction techniques

Many targets that remote sensing scientists encounter when conducting their research experiments do not lend themselves to laboratory measurement of their surface optical properties. Removal of these targets from the field can change their biotic condition, disturb the surface composition, and change the moisture content of the sample. These parameters, as well as numerous others, have a marked...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011