Accuracy of CT colonography for detection of large adenomas and cancers.

نویسندگان

  • C Daniel Johnson
  • Mei-Hsiu Chen
  • Alicia Y Toledano
  • Jay P Heiken
  • Abraham Dachman
  • Mark D Kuo
  • Christine O Menias
  • Betina Siewert
  • Jugesh I Cheema
  • Richard G Obregon
  • Jeff L Fidler
  • Peter Zimmerman
  • Karen M Horton
  • Kevin Coakley
  • Revathy B Iyer
  • Amy K Hara
  • Robert A Halvorsen
  • Giovanna Casola
  • Judy Yee
  • Benjamin A Herman
  • Lawrence J Burgart
  • Paul J Limburg
چکیده

BACKGROUND Computed tomographic (CT) colonography is a noninvasive option in screening for colorectal cancer. However, its accuracy as a screening tool in asymptomatic adults has not been well defined. METHODS We recruited 2600 asymptomatic study participants, 50 years of age or older, at 15 study centers. CT colonographic images were acquired with the use of standard bowel preparation, stool and fluid tagging, mechanical insufflation, and multidetector-row CT scanners (with 16 or more rows). Radiologists trained in CT colonography reported all lesions measuring 5 mm or more in diameter. Optical colonoscopy and histologic review were performed according to established clinical protocols at each center and served as the reference standard. The primary end point was detection by CT colonography of histologically confirmed large adenomas and adenocarcinomas (10 mm in diameter or larger) that had been detected by colonoscopy; detection of smaller colorectal lesions (6 to 9 mm in diameter) was also evaluated. RESULTS Complete data were available for 2531 participants (97%). For large adenomas and cancers, the mean (+/-SE) per-patient estimates of the sensitivity, specificity, positive and negative predictive values, and area under the receiver-operating-characteristic curve for CT colonography were 0.90+/-0.03, 0.86+/-0.02, 0.23+/-0.02, 0.99+/-<0.01, and 0.89+/-0.02, respectively. The sensitivity of 0.90 (i.e., 90%) indicates that CT colonography failed to detect a lesion measuring 10 mm or more in diameter in 10% of patients. The per-polyp sensitivity for large adenomas or cancers was 0.84+/-0.04. The per-patient sensitivity for detecting adenomas that were 6 mm or more in diameter was 0.78. CONCLUSIONS In this study of asymptomatic adults, CT colonographic screening identified 90% of subjects with adenomas or cancers measuring 10 mm or more in diameter. These findings augment published data on the role of CT colonography in screening patients with an average risk of colorectal cancer. (ClinicalTrials.gov number, NCT00084929; American College of Radiology Imaging Network [ACRIN] number, 6664.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CT colonography in cancer detection: methods and results

Colon cancer is the second leading cause of cancer-related death in the Western world. Approximately 80-90% of colon cancers develop in adenomas after mutations. The risk of encountering malignancy increases with the size of the adenomatous polyp. It is approximately 1% in adenomas <1 cm, and increases to 10% for adenomas 1-2 cm, and 20-53% for adenomas >2 cm. CT colonography (CTC) is a new tec...

متن کامل

CT colonography in detection of colorectal carcinoma

BACKGROUND Diagnostic methods used in screening and detecting colorectal carcinoma are digitorectal examination, faecal occult blood testing, sigmoidoscopy, DNA stool analysis, barium enema, colonoscopy, and as of recently CT colonography. The aim of this study was to establish diagnostic accuracy and comfort of CT colonography compared to colonoscopy and barium enema. PATIENTS AND METHODS We...

متن کامل

Diagnostic accuracy of computed tomographic colonography for the detection of advanced neoplasia in individuals at increased risk of colorectal cancer.

CONTEXT Computed tomographic (CT) colonography has been recognized as an alternative for colorectal cancer (CRC) screening in average-risk individuals, but less information is available on its performance in individuals at increased risk of CRC. OBJECTIVE To assess the accuracy of CT colonography in detecting advanced colorectal neoplasia in asymptomatic individuals at increased risk of CRC u...

متن کامل

Colon Capsule Endoscopy for the Detection of Colorectal Polyps: An Economic Analysis.

BACKGROUND Colorectal cancer is a leading cause of mortality and morbidity in Ontario. Most cases of colorectal cancer are preventable through early diagnosis and the removal of precancerous polyps. Colon capsule endoscopy is a non-invasive test for detecting colorectal polyps. OBJECTIVES The objectives of this analysis were to evaluate the cost-effectiveness and the impact on the Ontario hea...

متن کامل

Cost-effectiveness of computerized tomographic colonography versus colonoscopy for colorectal cancer screening.

BACKGROUND Computerized tomographic (CT) colonography is a potential alternative to colonoscopy for colorectal cancer screening. Its main advantage, a better safety profile, may be offset by its limitations: lower sensitivity, need for colonoscopy in cases where results are positive, and expense. METHODS We performed an economic evaluation, using decision analysis, to compare CT colonography ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The New England journal of medicine

دوره 359 12  شماره 

صفحات  -

تاریخ انتشار 2008