Analysis of residual crosslinking agent content in UV cross-linked poly(ethylene oxide) hydrogels for dermatological application by gas chromatography☆

نویسندگان

  • Rachel Shet Hui Wong
  • Mark Ashton
  • Kalliopi Dodou
چکیده

Acrylates have been widely used in the synthesis of pharmaceutical polymers. The quantitation of residual acrylate monomers is vital as they are strong irritants and allergens, but after polymerization, are relatively inert, causing no irritation and allergies. Poly(ethylene oxide) (PEO) hydrogels were prepared using pentaerythritol tetra-acrylate (PETRA) as UV crosslinking agent. A simple, accurate, and robust quantitation method was developed based on gas chromatographic techniques (GC), which is suitable for routine analysis of residual PETRA monomers in these hydrogels. Unreacted PETRA was initially identified using gas chromatography-mass spectrometry (GC-MS). The quantitation of analyte was performed and validated using gas chromatography equipped with a flame ionization detector (GC-FID). A linear relationship was obtained over the range of 0.0002%-0.0450% (m/m) with a correlation coefficient (r2) greater than 0.99. The recovery (>90%), intra-day precision (%RSD <0.67), inter-day precision (%RSD <2.5%), and robustness (%RSD <1.62%) of the method were within the acceptable values. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.0001% (m/m) and 0.0002% (m/m), respectively. This assay provides a simple and quick way of screening for residual acrylate monomer in hydrogels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Crosslinking Agent Concentration on the Properties of Unmedicated Hydrogels †

Novel polyethylene oxide (PEO) hydrogel films were synthesized via UV crosslinking with varying concentrations of pentaerythritol tetra-acrylate (PETRA) as crosslinking agent. The aim was to study the effects of the crosslinking agent on the material properties of hydrogel films intended for dermatological applications. Fabricated film samples were characterized using swelling studies, scanning...

متن کامل

Controlled release by using poly (methacrylic acid-g-ethylene glycol ) hydrogels

Graft copolymers of poly (ethylene glycol) with poly (methacrylic acid) were prepared by reaction of poly (ethylene glycol) methacrylate macromonomer with methacrylic acid in the presence of tetraethylene glycol dimethacrylate as a crosslinking agent. The materials were swollen in aqueous solutions with the pH ranging from 1.5 to 12.0. Dynamic swelling studies were performed. The swelling rates...

متن کامل

Controlled Release of Doxofylline from Biopolymer Based Hydrogels

In order to modify the xanthan gum (XG) polysaccharide and to develop the hydrogels meant for the drug delivery, we have prepared XG-g-poly [HEMA-co-AA] superporous hydrogel (SPH) through chemical cross-linking by graft copolymerization of 2-hydroxyethyl methacrylate (HEMA) and acrylic acid (AA) on to XG via redox initiator system of ammonium persulfate (APS) and N, N, N’, N’tetramethylethylene...

متن کامل

Synthesis of pH Sensitive Hydrogels Based on Poly Vinyl Alcohol and Poly Acrylic Acid

     In this research, hydrogels based on poly vinyl alcohol and poly acrylic acid blend were prepared which were cross-linked by applied thermal conditions. Afterward, effects of time and heating on water uptake were investigated. The highest water uptake value exhibited by the sample that was heated for 20 min. at 110 ºC was about 2129% after 4 days at equilibrium state. Hydrogels exhibited p...

متن کامل

Diffusion of small molecular weight drugs in radiation-crosslinked poly(ethylene oxide) hydrogels

Poly(ethylene oxide) (PEO) hydrogels were formed by crosslinking of aqueous PEO solutions of IVI = 35 000, 900 000 and 5 000 000 in concentrations of 5-50% using T-irradiation with 3-10 Mrad. The hydrogels were characterized by equilibrium swelling experiments. The average interjunction molecular weight, 1VI c, varied from 3500 to 32 000, whereas the mesh size, ~:, varied from 120 to 550 ,~. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016