Electron channeling: a problem for x-ray microanalysis in materials science.

نویسندگان

  • Frederick Meisenkothen
  • Robert Wheeler
  • Michael D Uchic
  • Robert D Kerns
  • Frank J Scheltens
چکیده

Electron channeling effects can create measurable signal intensity variations in all product signals that result from the scattering of the electron beam within a crystalline specimen. Of particular interest to the X-ray microanalyst are any variations that occur within the characteristic X-ray signal that are not directly related to a specimen composition variation. Many studies have documented the effect of crystallographic orientation on the local X-ray yield; however, the vast majority of these studies were carried out on thin foil specimens examined in transmission. Only a few studies have addressed these effects in bulk specimen materials, and these analyses were generally carried out at common scanning electron microscope microanalysis overvoltages (>1.5). At these overvoltage levels, the anomalous transmission effect is weak. As a result, the effect of electron channeling on the characteristic X-ray signal intensity has traditionally been overlooked in the field of quantitative electron probe microanalysis. The present work will demonstrate that electron channeling can produce X-ray variations of up to 26%, between intensity maxima and minima, in low overvoltage X-ray microanalyses of bulk specimens. Intensity variations of this magnitude will significantly impact the accuracy of qualitative and quantitative X-ray microanalyses at low overvoltage on engineering structural materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی تابش کانالی از ‌بلور‌های الماس به منظور تهیه پرتو X تک انرژی درشتاب دهنده خطی الکترون ELBE

The measurements of electron Channeling Radiation (CR) have been performed at ELBE linear electron accelerator of the Forschungszentrum Dresden-Rossendorf. The aim of performing these experiments was to optimize radiation yield and spectral line width of CR in order to apply channeling radiation for preparing a monochromatic X-ray source. Diamond crystals can be used in relatively high electron...

متن کامل

Synthesis and Characterization of Nano-Structure Copper Oxide From Two Different Copper (II) Metal-Organic Framework Precursors

Nano-structured copper oxides were successfully prepared through direct calcination of 1D ladderlike metal-organic framework [Cu2(btec)(2,2'-bipy)2]∞, (btec = 1,2,4,5-benzenetetracarboxylate and 2,2'-bipy = 2,2'-bipyridine) and porous coordination polymer [Cu(BDC)(bipy)](BDCH2), (BDC = 1,4-benzenedicarboxylate; bipy = 4,4'-bipyridine). The nano-structure of the as-synthesized samples are charac...

متن کامل

Electron Probe Microanalysis (EPMA)

An electron microprobe is an electron microscope designed for the non-destructive x-ray microanalysis and imaging of solid materials. It is essentially a hybrid instrument combining the capabilities of both the scanning electron microscope (SEM) and an x-ray fluorescence spectrometer (XRF), with the added features of fine-spot focusing (~ 1 micrometer), optical microscope imaging, and precision...

متن کامل

The Use of X-ray Microanalysis in the Study of Diffusion

This paper reviews the use of electron probe microanalysis, scanning electron microscopy and analytical electron microscopy in the measurement of compositional data obtained from diffusion couples. Methods to obtain x—ray spatial resolution as low as mm with the AEM are described. In addition, techniques for improving the detection and for increasing the accuracy of compositional analyses are s...

متن کامل

Performing elemental microanalysis with high accuracy and high precision by scanning electron microscopy/silicon drift detector energy-dispersive X-ray spectrometry (SEM/SDD-EDS).

Electron-excited X-ray microanalysis performed in the scanning electron microscope with energy-dispersive X-ray spectrometry (EDS) is a core technique for characterization of the microstructure of materials. The recent advances in EDS performance with the silicon drift detector (SDD) enable accuracy and precision equivalent to that of the high spectral resolution wavelength-dispersive spectrome...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada

دوره 15 2  شماره 

صفحات  -

تاریخ انتشار 2009