Preparing Drugs for Infusion Via Syringe Pump: A Key Step to Ensure Homogeneous Concentration.

نویسندگان

  • Bruno Garrigue
  • Yann Dehu
  • Fabrice Girault
  • Bruno Figadère
  • Karine Leblanc
  • Nicolas Briole
  • Georges Antoine Capitani
  • Steven Lagadec
  • François-Xavier Laborne
چکیده

OBJECTIVE Preparation of drug solutions used with electronic syringe infusion pumps plays a crucial role in the delivery of an accurate drug concentration. Is there a correlation between drug concentrations during syringe pump infusion and preparation protocols? METHOD Norepinephrine, insulin, and sufentanil were prepared in 3 different ways: (1) the drug was taken from the vial, then the solvent was added followed by an air bubble, and mixing was performed by turning the syringe top-to-bottom in a 180° shaking movement 5 consecutive times; (2) the drug was taken from the vial, then the solvent was added and not mixed; and (3) the solvent was taken from a stock solution, then the drug was added and not mixed. Concentrations of drugs were determined at different times during administration by reverse-phase high-performance liquid chromatography with ultraviolet detection. All analyses were performed in triplicate and were based on measurement of peak areas. RESULTS With no shaking of the syringe, the concentration of the injected drugs varies widely. In any case, mixing of the syringe contents by turning the syringe in a top-to-bottom 180° shaking movement 5 times with an air bubble would ensure administration of the drug at a constant concentration. CONCLUSIONS Without mixing, the concentrations of all drug solutions varied widely when administered via an electronic syringe infusion pump. Mixing syringe contents should be made part of the compulsory curriculum for administering medications at all levels of medical education. (Critical Care Nurse. 2016;36[4]:36-45).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Smart syringe pumps for drug infusion during dental intravenous sedation

Dentists often sedate patients in order to reduce their dental phobia and stress during dental treatment. Sedatives are administered through various routes such as oral, inhalation, and intravenous routes. Intravenous administration has the advantage of rapid onset of action, predictable duration of action, and easy titration. Typically, midazolam, propofol or dexmedetomidine are used as intrav...

متن کامل

Qualitative Application of Operation and Support Hazard Analysis for Syringe Infusion Pumps

In this paper, we provide a qualitative analysis with an experimental viewpoint for the Operation and Support Hazard Analysis O&SHA process applied to syringe infusion pumps as a cheap and accurate way of contributing with the mitigation of the safety problem in these devices. The proposed model takes as quality criteria the compliance within safety requirements defined by the Foods and Drugs A...

متن کامل

Downward movement of syringe pumps reduces syringe output.

We studied how lowering a syringe pump and changing the outflow pressure could affect syringe pump output. We experimentally reduced the height of three different syringe pump systems by 80 cm (adult setting) or 130 cm (neonatal setting), as can happen clinically, using five flow rates. We measured the time of backward flow, no flow and the total time without flow. An exponential negative corre...

متن کامل

غلظت‌سازی ترکیبات آلی فرار از مایعات خالص در فاز گازی

  Background and aims: Production of fixed concentration of vapors from pure liquid has many applications in laboratory and field studies of occupational health and toxicological research and also in calibration of air pollutant measurement devices of the workplaces. In this study, the advantages and disadvantages of different concentration generation methods were discussed. In addition two sel...

متن کامل

Efficacy evaluation of syringe pump developed for continuous drug infusion

BACKGROUND In dental intravenous sedation, continuous intravenous infusion of a low-dose drug requires an infusion pump such as a syringe pump. To develop a new syringe pump for clinical use, the functions of the pump must meet certain international standards. Various safety and efficacy tests must be performed on the syringe pump, as stipulated by these standards, and an approval must be recei...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical care nurse

دوره 36 4  شماره 

صفحات  -

تاریخ انتشار 2016