Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening patients with imported malaria in a non-endemic setting

نویسندگان

  • Camille Ponce
  • Flora Kaczorowski
  • Thomas Perpoint
  • Patrick Miailhes
  • Alain Sigal
  • Etienne Javouhey
  • Yves Gillet
  • Laurent Jacquin
  • Marion Douplat
  • Karim Tazarourte
  • Véronique Potinet
  • Bruno Simon
  • Adeline Lavoignat
  • Guillaume Bonnot
  • Fatimata Sow
  • Anne-Lise Bienvenu
  • Stéphane Picot
چکیده

BACKGROUND Sensitive and easy-to-perform methods for the diagnosis of malaria are not yet available. Improving the limit of detection and following the requirements for certification are issues to be addressed in both endemic and non-endemic settings. The aim of this study was to test whether loop-mediated isothermal amplification of DNA (LAMP) may be an alternative to microscopy or real-time PCR for the screening of imported malaria cases in non-endemic area. RESULTS 310 blood samples associated with 829 suspected cases of imported malaria were tested during a one year period. Microscopy (thin and thick stained blood slides, reference standard) was used for the diagnosis. Real-time PCR was used as a standard of truth, and LAMP (Meridian Malaria Plus) was used as an index test in a prospective study conducted following the Standards for Reporting Diagnosis Accuracy Studies. In the 83 positive samples, species identification was P. falciparum (n = 66), P. ovale (n = 9), P. vivax (n = 3) P. malariae (n = 3) and 2 co-infections with P. falciparum + P.malariae. Using LAMP methods, 93 samples gave positive results, including 4 false-positives. Sensitivity, specificity, positive predictive value and negative predictive value for LAMP tests were 100%, 98.13%, 95.51%, and 100% compared to PCR. CONCLUSION High negative predictive value, and limit of detection suggest that LAMP can be used for screening of imported malaria cases in non-endemic countries when expert microscopists are not immediately available. However, the rare occurrence of non-valid results and the need for species identification and quantification of positive samples preclude the use of LAMP as a single reference method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Loop-mediated isothermal amplification assay for rapid diagnosis of malaria infections in an area of endemicity in Thailand.

The loop-mediated isothermal amplification (LAMP) method, developed by our group for diagnosis of four human malaria parasites, was evaluated on a large scale at a remote clinic in Thailand where malaria is endemic. A total of 899 febrile patients were analyzed in this study. LAMP was first evaluated in 219 patients, and the result was compared to those of two histidine-rich protein (HRP)-2 rap...

متن کامل

Highly Sensitive Detection of Malaria Parasitemia in a Malaria-Endemic Setting: Performance of a New Loop-Mediated Isothermal Amplification Kit in a Remote Clinic in Uganda

BACKGROUND Current malaria diagnostic tests, including microscopy and antigen-detecting rapid tests, cannot reliably detect low-density infections. Molecular methods such as polymerase chain reaction (PCR) are highly sensitive but remain too complex for field deployment. A new commercial molecular assay based on loop-mediated isothermal amplification (LAMP) was assessed for field use. METHODS...

متن کامل

Evaluation of a new rapid molecular diagnostic system for Plasmodium falciparum combined with DNA filter paper, loop-mediated isothermal amplification, and melting curve analysis.

Falciparum malaria is a fatal infection without immediate diagnosability or treatment. There are shortages of clinicians and examiners skilled in the treatment of malaria in non-endemic countries, including Japan. This study was performed to evaluate a novel rapid molecular diagnostic system consisting of loop-mediated isothermal amplification (LAMP) combined with DNA filter paper (FTA card) an...

متن کامل

Rapid detection of infectious bursal disease by loop-mediated isothermal amplification for field analysis

Infectious bursal disease (IBD) is an immunosuppressive, acute and highly contagious illness of growing-poultry stock infected with infectious bursal disease virus (IBDV). It is common in Pakistan, causing potential economic losses throughout the year. The objective of the study is to propose a rapid, sensitive and specific diagnostic tool, and compare it with existing commonly used reverse tra...

متن کامل

Sensitivity of Loop-Mediated Isothermal Amplification Increases 100-Fold after TritonTM X-100 Treatment of Plasmodium-Infected Erythrocytes

Highly sensitive and rapid diagnostic methods that should also be appropriate for Point-of-Care (POC) testing are required for Mass Screening and Treatment (MSAT) programs to be effective in blocking transmission of malaria, and eventually eradicating the disease. Loop-Mediated Isothermal Amplification (LAMP) is an accurate, sensitive, rapid, and easy-to-perform method for gene amplification. P...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2017