An analysis of esophageal stent placement for persistent leak after the operative repair of intrathoracic esophageal perforations.
نویسندگان
چکیده
BACKGROUND Surgical repair of esophageal perforation has been the mainstay of therapy for patients without associated esophageal malignancy or diffuse mediastinal necrosis. However, the leak rate after primary surgical repair is reported to range between 15% and 20% and increases to 45% and 70% in patients whose repair is delayed beyond 24 hours. This analysis reviews patients who experienced a leak after the operative repair of an esophageal perforation treated with esophageal stent placement. METHODS Patients undergoing esophageal stent placement for the treatment of a leak after the operative repair of an intrathoracic esophageal perforation were identified from a single institution's database, which included patients initially treated at other facilities. Patient outcomes were recorded and analyzed. RESULTS During a 7-year period, 32 esophageal stents were placed in 29 patients who experienced an esophageal leak after operative repair. Associated surgical procedures were simultaneously performed in 7 (24%) patients. Leak occlusion occurred in 27 patients (93%). Two patients required a reoperative repair. Twenty-five patients (86%) were able to initiate oral nutrition within 72 hours of stent placement. Stent migration in 5 patients (19%) required repositioning (n=2) or replacement (n=3). Stents were removed at a mean of 22±16 days after placement. Mean hospital length of stay was 8±11 days. CONCLUSIONS Endoluminal esophageal stent placement is a safe and effective treatment for the majority of leaks after the operative repair of an intrathoracic esophageal perforation. Stent placement resulted in rapid leak occlusion and provided the opportunity for early oral nutrition while eliminating the need for reoperative repair or esophageal exclusion in the majority of patients.
منابع مشابه
Subclavian artery-esophageal fistula after placement of a self-expanding metal stent in a patient with esophagogastric anastomosis stenosis
Background: There have been reports on stent-related vascular erosions about patients with benign or malignant stenosis of the esophagus who received endoscopic stent insertion for palliative intention for oral intake. Case presentation: A 61-year-old woman with esophageal cancer located in the middle part of esophagus was treated with esophagectomy. Two years following the surgery, malignan...
متن کاملOptimal approach to the management of intrathoracic esophageal leak following esophagectomy: a systematic review.
BACKGROUND Recently, endoscopic interventions (eg, esophageal stenting) have been successfully used for the management of intrathoracic leak. The purpose of this systematic review was to assess the safety and efficacy of techniques used in the management of intrathoracic anastomotic leak. DATA SOURCES We performed a systematic review of MEDLINE, EMBASE, and PubMed to identify eligible studies...
متن کاملTreatment of intrathoracic esophageal anastomotic leaks by means of endoscopic stent implantation.
Intrathoracic anastomotic leakage in patients with esophagectomy is associated with high morbidity and mortality. Until recently surgical reexploration was the preferred way of dealing with this life-threatening complication. But mortality remained significant. After the first successful reports we adopted endoscopic stent implantation as a primary treatment option. The aim of this study was to...
متن کاملUtility of endoscopic therapy in the management of Boerhaave syndrome
Background/aims: The optimal intervention for Boerhaave perforation has not been determined. Options include surgical repair with/without a pedicled muscle flap, T tube placement, esophageal resection or diversion, or an endoscopic approach. All management strategies require adequate drainage and nutritional support. Our aim was to evaluate outcomes following Boerhaave perforation treated with ...
متن کاملCombined Placement of Covered Self-Expanding Metallic Stents and Nasojejunal Tube for Managing Large Lower Esophageal Perforations
Covered self-expanding metallic stents (cSEMSs) have emerged as effective treatment option for esophageal perforations. However, the large lower esophageal perforations where the cSEMS is placed across gastroesophageal junction have lower healing rates because refluxed gastric contents constantly irritate perforation and also there is increased risk of stent migration. Moreover, gastric mucosa ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of thoracic surgery
دوره 97 5 شماره
صفحات -
تاریخ انتشار 2014