THE EUROPEAN PHYSICAL JOURNAL C Measurement of theμ decay spectrum with the ICARUS liquid ArgonTPC

نویسندگان

  • C. Chen
  • D. Chen
  • D. B. Chen
  • Y. Chen
  • R. Cid
  • K. Cieślik
  • R. Santorelli
  • D. Scannicchio
  • E. Segreto
  • Y. Seo
چکیده

Examples are given which prove the ICARUS detector quality through relevant physics measurements. We study the μ decay energy spectrum from a sample of stopping μ events acquired during a also at IFSI del CNR, sezione presso LNF. 234 The ICARUS Collaboration: Measurement of the μ decay spectrum with the ICARUS liquid Argon TPC the test run of the ICARUS T600 detector. This detector allows the spatial reconstruction of the events with fine granularity, hence, the precise measurement of the range and dE/dx of the μ with high sampling rate. This information is used to compute the calibration factors needed for the full calorimetric reconstruction of the events. The Michel ρ parameter is then measured by comparison of the experimental and Monte Carlo simulated μ decay spectra, obtaining ρ = 0.72 ± 0.06 (stat.) ± 0.08 (syst.). The energy resolution for electrons below ∼ 50 MeV is finally extracted from the simulated sample, obtaining (E meas − E MC)/E MC = 11%/ √ E[MeV]⊕ 2%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Prediction of Thermo Physical, Vibrational Spectroscopy, Chemical Reactivity, Biological Properties of Morpholinium Borate, Phosphate, Chloride and Bromide Ionic Liquid: A DFT Study

In the light of computational chemistry, based on morpholinium cation-based Ionic Liquid, their different types of physical, chemical, and biological properties is highlighted. The physical properties are evaluated through the Density Functional Theory (DFT) of Molecular Mechanics and also examine the chemical and biological properties. The difference between Highest Occupied Molecular Orbital ...

متن کامل

0 v 1 1 9 N ov 2 00 3 Measurement of the μ decay spectrum with the ICARUS liquid Argon TPC

Examples are given which prove the ICARUS detector quality through relevant physics measurements. We study the μ decay energy spectrum from a sample of stopping μ events acquired during the test run of the ICARUS T600 detector. This detector allows the spatial reconstruction of the events with fine granularity, hence, the precise measurement of the range and dE/dx of the μ with high sampling ra...

متن کامل

0 v 2 1 2 Ja n 20 04 Measurement of the μ decay spectrum with the ICARUS liquid Argon TPC

Examples are given which prove the ICARUS detector quality through relevant physics measurements. We study the μ decay energy spectrum from a sample of stopping μ events acquired during the test run of the ICARUS T600 detector. This detector allows the spatial reconstruction of the events with fine granularity, hence, the precise measurement of the range and dE/dx of the μ with high sampling ra...

متن کامل

Results from the ICARUS T 600 module

We have studied the µ decay energy spectrum from a sample of stopping µ events acquired during the test run of the ICARUS T600 prototype. This detector allows the spatial reconstruction of the events with fine granularity, hence the precise measurement of the µ range and dE/dx with high sampling rate. This information is used to compute the correction factors needed for the calorimetric reconst...

متن کامل

A Model For The Residence Time Distribution and Holdup Measurement in a Two Impinging Streams Cyclone Reactor/Contactor in Solid-Liquid Systems

In this paper a two impinging streams cyclone contacting system suitable for handling of solid-liquid systems has been studied. Certain pertinent parameters such as: solid holdup, mean residence time and Residence Time Distribution (RTD) of solid particles have been investigated. A stochastic model based on Markov chains processes has been applied which describe the behavior of solid partic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004