Chromatographic selectivity triangles.

نویسندگان

  • Andrew R Johnson
  • Mark F Vitha
چکیده

2010 marked the 50th anniversary of the use of selectivity triangles to characterize chromatographic phases. Such plots ultimately identify and quantify the blend of intermolecular interactions that occur between solutes and solvents/phases. The first chromatographic triangle was proposed by Brown and applied to GC stationary phases. Snyder then developed the influential solvent selectivity triangle (SST) based on the gas-liquid partition data of Rohrschneider. The SST was combined with simplex experimental designs to optimize RPLC separations. Subsequent criticisms of the work revolved around the inaccurate predictions that resulted from the SST. These inaccuracies ultimately relate to the inability of the SST to account for the effects of water on the interaction ability of organic solvents. Other criticisms focused on the selection of the three probe solutes (ethanol, dioxane, and nitromethane) that were used to define the apices of the SST. Here, the concerns include the lack of explicit consideration of dispersion interactions and the fact that the three probes do not represent any single intermolecular interaction but rather reflect a blend of intermolecular interactions. The SST approach was modified for NPLC by redefining the triangle apices to reflect the localization, general adsorption, and basicity of NPLC mobile phase modifiers. Because water is generally absent in NPLC, the triangle approach leads to better predictions for NPLC than for RPLC. In subsequent modifications of selectivity triangles, Fu and Khaledi have created a micellar selectivity triangle (MST) based on linear solvation energy relationships (LSERs) and Zhang and Carr have used the Dolan-Snyder hydrophobic subtraction model to create RPLC column selectivity triangles. We end this review by highlighting more recent methods for comparing selectivities and by discussing a new 3D visualization tool for classifying chromatographic systems as having similar or different fundamental energetics of retention and hence having similar or different selectivities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Similar Triangles, Another Trace of the Golden Ratio

In this paper we investigate similar triangles which are not congruent but have two pair congruent sides. We show that greatest lower bound of values for similarity ratio of such triangles is golden ratio. For right triangles, we prove that the supremum of values for similarity ratio is the square root of the golden ratio.

متن کامل

Predicting gas chromatographic separation and stationary-phase selectivity using computer modeling.

A computer modeling technique has been developed which allows for the prediction of chromatographic separation and stationary-phase selectivity. This technique enables development of application-specific gas chromatographic columns by allowing for the simultaneous optimization of physical dimensions, flow and temperature programs, and stationary-phase composition. Stationary-phase selectivity i...

متن کامل

Study of selectivity of molecularly imprinted polymers prepared under different conditions.

Molecularly imprinted polymers were prepared and tested in different ways. 1-Methyl-2-piperidinoethylester of 4-decyloxyphenylcarbamic acid was used as the template for imprints formation. Acrylamide, 4-vinylpyridine, and methacrylic acid as monomers and methanol and acetonitrile as a porogene were used. Non-imprinted polymers were prepared for each imprinted polymer by the same procedure. Poly...

متن کامل

Rapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method

An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1218 4  شماره 

صفحات  -

تاریخ انتشار 2011