Arterial access-site complications after use of a vascular closure device related to puncture height
نویسندگان
چکیده
BACKGROUND To analyze differences of access-site complications related to the height of femoral arterial puncture and the use of a vascular closure device (VCD) following percutaneous coronary intervention (PCI). METHODS A subgroup of the FERARI study being treated by femoral arterial access and valuable inguinal angiography before implantation of a VCD were included. Inguinal angiographies were systematically reviewed by two independent cardiologists to determine the correct height of femoral arterial puncture. Bleeding complications were documented within 30 days after PCI and were categorized according to BARC, TIMI, GUSTO and FERARI classifications. RESULTS Femoral access point imaging was available in 95 patients compared to 105 patients without. The common femoral artery (CFA) was the most accessed artery in 41%, followed by the femoral arterial bifurcation (39%) and lower access sites distally from the femoral arterial bifurcation (low puncture: 20%). No differences were observed regarding indication of PCI, procedural data and anticoagulation therapies in relation to the heights of femoral arterial access (p > 0.05). Despite using VCD, arterial puncture at the CFA resulted in numerically highest numbers of overall bleedings (62%) compared to femoral arterial bifurcation (41%) (p = 0.059). 58% of bleedings occurred after arterial puncture below the femoral bifurcation (low puncture). Though no significant differences of bleedings regarding classifications of BARC, GUSTO, TIMI and FERARI as well as other vascular endpoints were observed regarding puncture height. CONCLUSIONS The present analysis demonstrates no significant differences of bleeding complications in relation to the height of femoral arterial puncture and subsequent use of a VCD.
منابع مشابه
Exoseal for puncture site closure after antegrade procedures in peripheral arterial disease patients.
PURPOSE Exoseal is a vascular clo-sure device consisting of a plug applier and a bio-absorbent polyglycolic acid plug available in sizes 5 F, 6 F, and 7 F. In this study, we aimed to evaluate the effectiveness and safety of the Exoseal vascular closure device (Cordis Corporation, Bridgewater, New Jersey, USA) for puncture site closure after antegrade endovascular procedures in peripheral arteri...
متن کاملDesign and rationale of the AngioSeal versus the Radial approach In acute coronary SyndromE (ARISE) trial: a randomized comparison of a vascular closure device versus the radial approach to prevent vascular access site complications in non-ST-segment elevation acute coronary syndrome patients
BACKGROUND Arterial access is a major site of bleeding complications after invasive coronary procedures. Among strategies to decrease vascular complications, the radial approach is an established one. Vascular closure devices provide more comfort to patients and decrease hemostasis and need for bed rest. However, the inconsistency of data proving their safety limits their routine adoption as a ...
متن کاملMeta-analysis of randomized trials on the efficacy of vascular closure devices after diagnostic angiography and angioplasty.
BACKGROUND The aim of this meta-analysis was to evaluate the safety and efficacy of vascular closure devices (VCDs). METHODS This meta-analysis was performed in accordance with the Cochrane Handbook for Systematic Reviews. RESULTS The literature search yielded 31 prospective, randomized studies including 7,528 patients who were randomized to VCDs or manual/mechanical compression after diagn...
متن کاملA Modified Technique to Safely Close the Arterial Puncture Site After TAVI.
BACKGROUND We describe a vascular closure technique, convenient in practice, that permits effective femoral artery closure after CoreValve (Medtronic) implantation during transcatheter aortic valve implantation (TAVI). Vascular complications of transfemoral access implantation have been associated with significantly increased patient morbidity and mortality, as well as with increased hospitaliz...
متن کاملSurgical treatment of complications associated with the angio-seal vascular closure device: report of three cases.
The Angio-Seal arterial closure device consists of several bioabsorbable components and is used for hemostasis of arterial puncture sites. We report 3 cases of hemorrhagic and ischemic complications related to Angio-Seal use. Two cases were treated successfully by surgical removal of the device. In the third case surgical removal of the device failed and additional intervention was necessary. T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2017