Does the measurement of liver and vertebral fat content influenced by R2* effect in T2*-IDEAL: A comparison study with 3-point IDEAL and MRS in healthy volunteers

نویسندگان

  • C-J. Juan
  • H-C. Chang
  • C-Y. Yu
  • C-H. Liou
  • C-Y. Chen
  • C-J. Hsueh
  • H-W. Kao
  • C-W. Wang
  • H-W. Chung
  • G-S. Huang
چکیده

Introduction Three-point Dixon IDEAL (iterative decomposition of water and fat with echo asymmetry and least-squares estimation, 3-pt IDEAL) techniques have been used to estimate liver fat content [1]. A multi-echo reconstruction technique, T2*-IDEAL, allows simultaneous measurement of water content, fat content, and T2* [2]. The T2*-IDEAL technique is able to estimate fat-content of liver in the presence of iron overload. The effects of T2* on the signal intensity of fat and water and subsequent fat content calculation on liver and vertebra have not been investigated yet. In this study, we aimed to verify the measurement difference of T2*-IDEAL on signal intensity and fat content of liver and lumbar vertebra compared to the 3-pt IDEAL. Material and method This preliminary study enrolled 13 healthy volunteers (7 men, 6 women, 44.1 ± 15.9 years) who were free any hepatic disease or iron deposition-related disease. 3D SPGR sequence was used for sequential acquisitions at three TEs (1.68/3.24/4.80 ms) for 3-pt IDEAL reconstruction with scanning parameters including TR (7.55 ms), matrix (256 × 128), BW (62.15kHz), slice thickness (8mm), slice number (8) and scan time (19 seconds). A multi-echo 3D SPGR sequence with flyback gradient readout was used to acquire six TEs (1.63/4.49/7.35/10.21/13.07/15.93 ms) for T2*-IDEAL reconstruction, with scanning parameters including TR (18.18 ms), slice thickness (8mm), slice/slab number (8). Two sets of images were acquired for T2*-IDEAL reconstruction using matrix size of 256 × 128 and 256 × 224 with a scan time of 9 seconds and 17 seconds, respectively. Three sets of images including fat-only, water-only and fat-fraction images were calculated form aforementioned protocols (Fig. 1). R2* maps were calculated from T2*-IDEAL reconstructions. For comparison, an additional H MRS scan (TE/TR: 30/3000ms, voxel size: 1x1x2cm) was also performed for fat content estimation. For measurements of fat content and R2* values, five ROIs were placed in the periphery of the right lobe liver parenchyma and another ROI was placed in the marrow of the lumbar vertebra as illustrated (Fig. 1). The H MRS is processed using SAGE (research software of GE, US) for calculating the area of fat peak at 1.3 ppm and the area of water peak at 4.7ppm. Statistical analyses were performed by using SPSS 13.0 (SPSS, Chicago, Ill). Normality of the perfusion parameters was examined using Q-Q plots and Kolmogorov-Smirnov tests. Student t test was used for group comparisons of ADC. Linear regression analysis was used for correlation analysis of liver fat content measured by IDEAL versus MRS. A P value of less than 0.05 was considered as statistically significant. Results: The liver fat contents measured by 3-pt IDEAL and T2* IDEAL were significantly correlated with that measured by MRS with a correlation coefficient higher than 0.95 (P < 0.005) (Fig. 2). The R2* value was significantly higher in vertebra (127.98 ± 53.23) than in liver (34.61 ± 14.10) (P < 0.005). The liver fat content (7.03 ± 5.11%) was significantly lower than the vertebral fat content (46.25 ± 8.75%) (P < 0.005) (Fig. 3). In the liver, there was no difference regarding the signal intensity of fat, the signal intensity of water and the fat content measured by 3-pt IDEAL and T2* IDEAL (all P > 0.05). In the vertebra, the signal intensity of fat and water measured by T2* IDEAL was significantly lower than that measured by 3-pt IDEAL (P < 0.005), while the fat content measured by 3-pt IDEAL was in consistent with that measured by T2* IDEAL (all P > 0.05) (Fig. 3).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of T2* Estimation with Chemical Shift-Based Water-Fat Separated Cardiac Imaging

Introduction T2* mapping has been investigated in cardiac MRI for imaging the myocardial BOLD effect [1] and in iron overload assessment [2]. Advanced T2* estimation techniques in the context of chemical shift-based water-fat decomposition have recently been developed for iron detection in organs such as the liver, while simultaneously estimating fat content [3]. Separately, chemical shiftbased...

متن کامل

Comparison of fat-water MRI and single-voxel MRS in the assessment of hepatic and pancreatic fat fractions in humans.

The ability to accurately and noninvasively quantify fatty infiltration in organs such as the liver and the pancreas remains a critical component in understanding the link between obesity and its comorbidities such as type 2 diabetes and fatty liver disease. Single-voxel ((1)H) proton magnetic resonance spectroscopy (MRS) has long been regarded as the gold-standard noninvasive technique for suc...

متن کامل

Comparison between BMI and Inverted BMI in Evaluating Metabolic Risk and Body Composition in Iranian Children

Objectives: To compare BMI and inverted BMI in evaluating body measurement, resting blood pressure, Dual energy X-ray absorptiometry (DEXA) parameters of fat mass and metabolic risk factors in Iranian children Materials and Methods: This is a cross-sectional study on 477 children aged 9-18 yearsin the South of Iran. Weight, height, resting blood pressure, waist and hip circumference and puberta...

متن کامل

Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)

Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different   and  weighting for liver fat quantification in patients with...

متن کامل

On the effect of low-quality node observation on learning over incremental adaptive networks

In this paper, we study the impact of low-quality node on the performance of incremental least mean square (ILMS) adaptive networks. Adaptive networks involve many nodes with adaptation and learning capabilities. Low-quality mode in the performance of a node in a practical sensor network is modeled by the observation of pure noise (its observation noise) that leads to an unreliable measurement....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009