Multielement determination of cadmium and lead in urine by simultaneous electrothermal atomic absorption spectrometry with an end-capped graphite tube.
نویسندگان
چکیده
A method for the multielement determination of cadmium and lead in urine is proposed by simultaneous electrothermal atomic absorption spectrometry (SIMAAS) with an end-capped transversely heated graphite atomizer (EC-THGA). The best conditions for cadmium and lead determination were obtained in the presence of NH4H2PO4 as a chemical modifier, using 500 degrees C and 1800 degrees C as the pyrolysis and atomization temperatures, respectively. Urine samples were diluted 1 + 4 directly in autosampler cups with a mixture of 0.125% (w/v) Triton X-100 + 2.5% (v/v) HNO3 + 0.31% (w/v) NH4H2PO4. The optimized heating program was carried out in 57 s, and the instrument calibration was done with aqueous reference solutions. The use of EC-THGA increased the sensitivity of cadmium and lead by 14% and 25%, respectively. The detection limits (n = 20, 3delta) were 0.03 microg L(-1) (0.36 pg) for cadmium and 0.57 microg L(-1) (6.8 pg) for lead. The performance of EC-THGA was acceptable up to 500 heating cycles. The reliability of the entire procedure was checked with the analysis of a lyophilized urine certified reference material. The found concentrations were in agreement with the recommended values (95% confidence level).
منابع مشابه
Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry
A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...
متن کاملDetermination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop
The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...
متن کاملElectrothermal atomic absorption spectrometric determination of cadmium and lead in environmental, botanic and biological samples by different permanent modifiers{
Permanent modifiers (Zr, W, Ru, Zr–Ru and Zr–W) thermally deposited on platforms inserted in pyrolytic graphite tubes and Pd 1 Mg(NO3)2 conventional modifier mixture have been employed for the determination of cadmium and lead in dissolved environmental, botanic and biological samples by electrothermal atomic absorption spectrometry (ETAAS). Optimum masses and mass ratios of permanent modifiers...
متن کاملDetermination of cadmium in wine by electrothermal atomic absorption spectrometry.
A method is described for direct electrothermal atomic absorption spectrometric (ETAAS) determination of cadmium in untreated samples of wine. Pyrolytic graphite tubes and graphite tubes with standard L'vov pyrolytic platforms were tested as atomizers. The detection limit achieved was 0.08 microg L(-1) Cd in wine. The relative standard deviation for the concentration range from 0.2 to 10 microg...
متن کاملUtilization of electrodeposition on a graphite probe modified with palladium in determination of lead by graphite furnace atomic absorption spectrometry in water and environmental samples
In this work a rapid and selective procedure for separation and preconcentration of lead(Pb2+) before determination by electrothermal atomic absorption spectrometry (ETAAS) wasdeveloped. The procedure is based on the electrodeposition on a graphite probe modified withpalladium. The lead was deposited from acetate buffer solution at pH 5.5. Various parameters,such as pH of solutions, deposition ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 19 11 شماره
صفحات -
تاریخ انتشار 2003