Disturbance Elimination for Partial Discharge Detection in the Spacer of Gas-Insulated Switchgears
نویسندگان
چکیده
With the increasing demand for precise condition monitoring and diagnosis of gas-insulated switchgears (GISs), it has become a challenge to improve the detection sensitivity of partial discharge (PD) induced in the GIS spacer. This paper deals with the elimination of the capacitive component from the phase-resolved partial discharge (PRPD) signal generated in GIS spacers based on discrete wavelet transform (WT). Three types of typical insulation defects were simulated using PD cells. The single PD pulses were detected and were further used to determine the optimal mother wavelet. As a result, the bior6.8 was selected to decompose the PD signal into 8 levels and the signal energy at each level was calculated. The decomposed components related with capacitive disturbance were discarded, whereas those associated with PD were de-noised by a threshold and a thresholding function. Finally, the PRPD signals were reconstructed using the de-noised components.
منابع مشابه
Detection in Spacer of Gas-Insulated Switchgears
With the increasing demand for precise condition monitoring and diagnosis of 11 gas-insulated switchgears (GIS), it has become a challenge to improve the detection sensitivity of 12 partial discharge (PD) induced in the GIS spacer. This paper deals with the elimination of the 13 capacitive component from the phase resolved partial discharge (PRPD) signal generated in GIS 14 spacer based on the ...
متن کاملInvestigation of Gas-Sensing Property of Acid-Deposited Polyaniline Thin-Film Sensors for Detecting H2S and SO2
Latent insulation defects introduced in manufacturing process of gas-insulated switchgears can lead to partial discharge during long-time operation, even to insulation fault if partial discharge develops further. Monitoring of decomposed components of SF₆, insulating medium of gas-insulated switchgear, is a feasible method of early-warning to avoid the occurrence of sudden fault. Polyaniline th...
متن کاملInception Level of Partial Discharges in SF6 Induced with Short X-Ray Pulses
First generation gas insulated switchgears were constructed with large safety margin. Today’s trend is to reduce the size of the switchgears to save material and costs. With increased field strength due to reduced dimensions as well as increased pressure in the compartments, the influence of surface roughness, surface damages and conducting particles is increasing. Therefore the knowledge of th...
متن کاملDependence of Particle Initiated PD Characteristics on Size and Position of Metallic Particle Adhering to the Spacer Surface in GIS
It is well known that metallic particles reduce the reliability of Gas-Insulated Substation (GIS) equipments by initiating partial discharge (PDs) that can lead to breakdown and complete failure of GIS. This paper investigates the characteristics of PDs caused by metallic particle adhering to the solid spacer. The PD detection and measurement were carried out by using IEC 60270 method with part...
متن کاملAdsorption of SF6 decomposed gas on anatase (101) and (001) surfaces with oxygen defect: A density functional theory study
The detection of partial discharge by analyzing the components of SF6 gas in gas-insulated switchgears is important to the diagnosis and assessment of the operational state of power equipment. A gas sensor based on anatase TiO2 is used to detect decomposed gases in SF6. In this paper, first-principle density functional theory calculations are adopted to analyze the adsorption of SO2, SOF2, and ...