Reading with a Simulated 60-Channel Implant
نویسندگان
چکیده
First generation retinal prostheses containing 50-60 electrodes are currently in clinical trials. The purpose of this study was to evaluate the theoretical upper limit (best possible) reading performance attainable with a state-of-the-art 60-channel retinal implant and to find the optimum viewing conditions for the task. Four normal volunteers performed full-page text reading tasks with a low-resolution, 60-pixel viewing window that was stabilized in the central visual field. Two parameters were systematically varied: (1) spatial resolution (image magnification) and (2) the orientation of the rectangular viewing window. Performance was measured in terms of reading accuracy (% of correctly read words) and reading rates (words/min). Maximum reading performances were reached at spatial resolutions between 3.6 and 6 pixels/char. Performance declined outside this range for all subjects. In optimum viewing conditions (4.5 pixels/char), subjects achieved almost perfect reading accuracy and mean reading rates of 26 words/min for the vertical viewing window and of 34 words/min for the horizontal viewing window. These results suggest that, theoretically, some reading abilities can be restored with actual state-of-the-art retinal implant prototypes if "image magnification" is within an "optimum range." Future retinal implants providing higher pixel resolutions, thus allowing for a wider visual span might allow faster reading rates.
منابع مشابه
An Accurate 2D Analytical Model for Transconductance to Drain Current ratio (gm/Id) for a Dual Halo Dual Dielectric Triple Material Cylindrical Gate All Around MOSFETs
A dual-halo dual-dielectric triple-material cylindrical-gate-all-around/surrounding gate (DH-DD-TM-CGAA/SG) MOSFET has been proposed and an analytical model for the transconductance-to-drain current ratio (TDCR) has been developed. It is verified that incorporation of dual-halo with dual-dielectric and triple-material results in enhancing the device performance in terms of improved TDCR. The ef...
متن کاملتعیین توزیع تنش و کرنش استخوان اطراف ایمپلنت در طرح All-on-4 به روش آنالیز اجزای محدود
Background and Aims: The All-on-4 design with its significant advantages is an appropriate model in reconstruction of edentulous mandible. Evaluation of stress and strain distribution in this model is necessary for better judgment. The purpose of this FEA study was to measure stress and strain distribution on peri-implant bone in All-on-4 design in edentulous mandible. Materials and Methods: Th...
متن کاملSimulating the effect of cochlear-implant electrode insertion depth on speech understanding.
Normally hearing listeners were presented with vowels, consonants, and sentences for identification through an acoustic simulation of a five-channel cochlear implant with electrodes separated by 4 mm (as in the Ineraid implant). The aim of the experiment was to simulate the effect of depth of electrode insertion on identification accuracy. Insertion depth was simulated by outputting sine waves ...
متن کاملتعیین توزیع تنش استخوان اطراف ایمپلنتهای فک پایین در طرحهای مختلف پروتز به هنگام Mandibular- Flexure
Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...
متن کاملLaminar Flow Analysis in the Channel Bends
In this paper the laminar flow in the rectangular channel bends is simulated using numerical techniques. The turning angle of the channel bend and the area ratio of the channel cross-section are two important parameters to be examined. For flow simulation, the body fitted 3-D continuity and momentum equations are used and a body fitted general purpose code is developed. The existing results of ...
متن کامل