Dosimetry of a 188rhenium-labeled self-expanding stent for endovascular brachytherapy in peripheral arteries.

نویسندگان

  • B Nowak
  • J M Meyer
  • T Goergen
  • D Fluehs
  • S Block
  • R W Guenther
  • H Hoecker
  • U Buell
چکیده

PURPOSE Radioactive stents have been proposed as endovascular irradiation device to prevent in-stent restenosis by inhibiting neointimal proliferation. 32P-stents have been used in several studies so far, but require large-scale labeling procedures and endovascular barotrauma for stent expansion supporting the development of edge restenosis. Purpose of this study was to establish dosimetry of a self-expanding nitinol stent for peripheral vascular disease, which was radiolabeled with 188rhenium (188Re) by a dip coating technique. METHODS AND MATERIALS The surface of nitinol Memotherm FLEXX stents was polymer-coated providing functional NH(2) groups for diethylenetriaminepentaacetic acid (DTPA) binding, providing the ligand for the complexation of 188Re onto the stent surface. Stability of radiolabeling was tested over 48 h using an in vitro blood circulation (Chandler Loop). Radial and longitudinal dose distributions of a radiolabeled stent were obtained with a plastic scintillator dosimetry system. RESULTS Stents with a length of 30 mm and a diameter of 8 mm were labeled with up to 33 MBq 188Re. A total of 69+/-4% of the labeled 188Re remained stable on the stent surface after 48 h. Ninety-five percent of the infinitely accumulated dose was supplied to the target tissue within 72 h. Including correction for radioactivity washout from the stent, the infinitely accumulated dose at 1 mm radial distance from the stent surface was 1.85+/-0.19 Gy/MBq 188Re/cm stent length. CONCLUSIONS We developed a technique for radiolabeling of self-expanding nitinol stents with 188Re by dip coating and formation of 188Re chelate complexes. We provide dosimetry data useful for application of this beta-emitting stent for endovascular brachytherapy in peripheral vascular occlusive disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subclavian artery-esophageal fistula after placement of a self-expanding metal stent in a patient with esophagogastric anastomosis stenosis

Background: There have been reports on stent-related vascular erosions about patients with benign or malignant stenosis of the esophagus who received endoscopic stent insertion for palliative intention for oral intake. Case presentation: A 61-year-old woman with esophageal cancer located in the middle part of esophagus was treated with esophagectomy. Two years following the surgery, malignan...

متن کامل

Dosimetry of 188Re and 186Re sources based on Monte Carlo calculations for endovascular brachytherapy after balloon angioplasty

Background: Recent pre-clinical and clinical studies indicate that irradiation in the dose range of 15 to 30 Gy can reduce rate of restenosis in patients who have undergone an angioplasty. The use of filled balloon with radioactive solution was proposed as one of the possible intravascular irradiation techniques. Materials and Methods: The Monte Carlo N-particle Transport Code (MCNP4b) was used...

متن کامل

Emerging Stent and Balloon Technologies in the Femoropopliteal Arteries

Endovascular procedures for the management of the superficial femoral (SFA) and popliteal artery disease are increasingly common. Over the past decade, several stent technologies have been established which may offer new options for improved clinical outcomes. This paper reviews the current evidence for SFA and popliteal artery angioplasty and stenting, with a focus on randomized trials and reg...

متن کامل

Modeling and dose calculations of a pure beta emitting 32P coated stent for intracoronary brachytherapy by Monte Carlo code

Background: Recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. In this study a unique radioactive source for intra vascular brachytherapy (IVBT) was investigated. The two-dimensional dose distribution in water for a 32P IVBT stent has been calculated. The pure beta emitter source 32P has been co...

متن کامل

Overview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent

Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cardiovascular radiation medicine

دوره 2 4  شماره 

صفحات  -

تاریخ انتشار 2001