Acute Patellar Tendon Rupture after Total Knee Arthroplasty Revision

نویسندگان

  • Seung Joon Rhee
  • The Hien Pham
  • Jeung Tak Suh
چکیده

Patellar tendon rupture is a catastrophic complication following total knee arthroplasty (TKA). Though revision TKA has been suspected of being a predisposing factor for the occurrence of patellar tendon rupture, there are few reports on patellar tendon rupture after revision TKA. Here, we present a case of acute patellar tendon rupture that occurred after TKA revision. In the patient, the patellar tendon was so thin and could not be repaired, and accordingly was sutured end to end. We used the anterior tibialis tendon allograft to augment the poor quality patellar tendon tissue. Fixation of the allograft was done by using the bone tunnel created through tibial tuberosity and suturing the allograft to the patellar tendon and quadriceps tendon. The patient was instructed to wear a full extension knee splint and was kept non-weight bearing for 6 weeks after operation. Full knee extension could be achieved 6 weeks postoperatively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bilateral extensor mechanism disruption after total knee arthroplasty in two morbidly obese patients.

Disruption of the extensor mechanism as a result of patellar tendon or quadriceps tendon rupture is an uncommon but devastating complication after total knee arthroplasty. Treating a disrupted extensor mechanism can be challenging, particularly in patients who are morbidly obese, due to an increased risk of postoperative complications. Therefore, despite the debilitating nature of extensor mech...

متن کامل

Extensor Mechanism Disruption after Total Knee Arthroplasty: A Case Series and Review of Literature.

Extensor mechanism disruption following total knee arthroplasty (TKA) is a rare but devastating complication. These patients may require revision of the implants, but even then, it may not be possible to restore the normal function of the knee after the disruption. The patterns of extensor mechanism disruption can broadly be classified into three types: suprapatellar (quadriceps tendon rupture)...

متن کامل

Patellar instability after total knee arthroplasty.

Twenty-five knees with symptomatic lateral patellar instability after total knee arthroplasty (TKA) were treated by operative realignment. Causes of instability include errors in surgical technique, quadriceps imbalance, and trauma. Fourteen knees had proximal realignment, nine had combined proximal and distal realignment, and two had component revision. At an average follow-up period of 50 mon...

متن کامل

Bilateral Spontaneous Midsubstance Patellar Tendon Rupture after Bilateral Total Knee Arthroplasty

INTRODUCTION Patellar tendon rupture can occur due to multiple causes ranging from inflammatory pathologies to episodes of trauma. Extensor mechanism rupture is a rare complication of total knee arthroplasty (TKA). In most of these cases, the failure occurs as avulsion of patellar tendon from tibial tuberosity. We report a rare case with bilateral mid-substance patellar tendon rupture one month...

متن کامل

Chronic Quadriceps Tendon Rupture After Total Knee Arthroplasty Augmented With Synthetic Mesh.

Tear of the quadriceps tendon after revision or primary total knee arthroplasty is a rare complication, but when it occurs, this injury has serious functional consequences. In complete tears, the outcome of direct repair is unpredictable, and several authors recommend that the suture should be reinforced. Several techniques have been described, including the use of autografts, allografts, and s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 27  شماره 

صفحات  -

تاریخ انتشار 2015