The development and application of a high throughput aqueous solubility assay is reported. Measurements for up to 637 compounds can be made in a fully automated experiment. Results from this assay were used to quantify risk of unacceptable solubility as a function of lipophilicity for neutral fragment-like compounds. Assessment of risk of unacceptable solubility was combined with experimental solubility measurement to select compounds for inclusion in a fragment-screening library.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fragment library design_Layout 1

Hit Generation (FBHG) overcomes many of the potential issues and inaccuracies encountered with the traditional approach of high throughput screening (HTS). For example, traditional screening libraries are commonly populated with molecules designed to adhere to Lipinski’s rule of five; however, they tend to be large and lipophilic, making them difficult to develop into potent compounds without c...

متن کامل

Fragment-based activity space: smaller is better.

Fragment-based drug discovery has the potential to supersede traditional high throughput screening based drug discovery for molecular targets amenable to structure determination. This is because the chemical diversity coverage is better accomplished by a fragment collection of reasonable size than by larger HTS collections. Furthermore, fragments have the potential to be efficient target binder...

متن کامل

DNA Sequence Fragment Containing C to A Mutation as a Convenient Mutation Standard for DHPLC Analysis

Objective(s):  Denaturing high performance liquid chromatography (DHPLC) is a high throughput approach for screening DNA sequence variations. To assess oven calibration, cartridge performance, buffer composition and stability, the WAVE Low and High Range Mutation Standards are employed to ensure reproducibility and accuracy of the chromatographic analysis. The purpose of this study was to provi...

متن کامل

Nootropic Medicinal Plants; Evaluating Potent Formulation By Novelestic High throughput Pharmacological Screening (HTPS) Method

The principle of this method was to screen the pharmacological activity of six prepared polyphyto formulations by using high throughput screening method for their nootropic action. The study was performed in three stages using one, two and three animals, respectively in a group. Test formulations were given p.o daily at the dose of 50 and 100 mg/kg body weight. The test formulations were compar...

متن کامل

Introducing weak affinity chromatography to drug discovery with focus on fragment screening

Duong-Thi, Minh-Dao (2013). Introducing Weak Affinity Chromatography to Drug Discovery with Focus on Fragment Screening. Linnaeus University Dissertations No 124/2013. ISBN: 978-91-87427-14-5. Written in English. Fragment-based drug discovery is an emerging process that has gained popularity in recent years. The process starts from small molecules called fragments. One major step in fragment-ba...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bioorganic & medicinal chemistry

دوره 16 13  شماره 

صفحات  -

تاریخ انتشار 2008