A New Design of a Lead-Acrylic Shield for Staff Dose Reduction in Radial and Femoral Access Coronary Catheterization.
نویسندگان
چکیده
PURPOSE Today's standard radiation protection during coronary angiography and percutaneous coronary interventions is the combined use of lead acrylic shields and table-mounted lower body protection. Ambient dose measurements, however, have shown that these protection devices need improvement. MATERIALS AND METHODS Using an anthropomorphic physical phantom, various scenarios were investigated with respect to personnel exposure: a) enlarging the shield b) adding a flexible protective curtain to the bottom side of the shield, and c) application of radioprotective patient drapes. For visualization of the dose reduction effect, Monte Carlo simulations were performed. RESULTS The flexible curtain in contact with the patient's body reduces the ambient dose rate at the operator's position by up to (87.5% ± 7.1) compared to the situation with the bare shield. The use of both the flexible curtain and the patient drape reduces the ambient dose rate by up to (90.8% ± 7). Similar results were achieved for the assisting personnel when they were positioned next to the operator. In addition, the enlarged shield provides better protection of the head region of tall operators. CONCLUSION Adding a flexible protective curtain to the bottom side of the shield can protect operators from high doses, especially for body parts which are not protected by lead aprons, e.g. head, and eye lenses. This may be important with respect to lower dose limits for eye lenses in future. The protective effect in real-life working conditions is still being evaluated in an ongoing clinical study. KEY POINTS Lead acrylic shields need improvement for a better protection of head and eye lenses. An additional flexible lead curtain at the bottom of the shield can considerably reduce the operator dose. Using the additional lead curtain, lighter protection clothing can be worn. Special eye protection may be no longer needed in most applications.
منابع مشابه
Reduction of operator radiation dose by a pelvic lead shield during cardiac catheterization by radial access: comparison with femoral access.
OBJECTIVES This study sought to determine the efficacy of patient pelvic lead shielding for the reduction of operator radiation exposure during cardiac catheterization via the radial access in comparison with the femoral access. BACKGROUND Cardiac catheterization via the radial access is associated with significantly increased radiation dose to the patient and the operator. Improvements in ra...
متن کاملRadiation Dose Reduction during Radial Cardiac Catheterization: Evaluation of a Dedicated Radial Angiography Absorption Shielding Drape
Objectives. Radiation scatter protection shield drapes have been designed with the goal of decreasing radiation dose to the operators during transfemoral catheterization. We sought to investigate the impact on operator radiation exposure of various shielding drapes specifically designed for the radial approach. Background. Radial access for cardiac catheterization has increased due to improved ...
متن کاملComparison of the patient radiation exposure during coronary angiography and angioplasty procedures using trans-radial and trans-femoral access
INTRODUCTION Cardiac catheterization procedure through the trans-radial access (TRA) have shown many clinical advantages over the trans-femoral (TFA), but despite its advantages, there are serious concerns regarding higher possible radiation dose for the patients and operators in TRA. This study was planned to compare the patients' radiation dose associated with TRA and TFA during coronary angi...
متن کاملبررسی و مقایسه ی دز مؤثر چشم راست و چپ کاردیولوژیست در آنژیوگرافی های فمورال و رادیال در یکی از بیمارستان های مهران
Background and Aim: Coronary angiography (CA) is a diagnostic and therapeutic procedure for cardiac complexity, that has a high dose and high fluoroscopy time. The effective dose of eye lens as a radiosensitive organ in long-term exposure to CA must be evaluated. Materials and Methods: A cross-sectional study was performed with Siemens under-bed machine in Imam Hossein Hospital of Mehran, Ilam...
متن کاملTrans-radial versus trans-femoral access in patients with end-stage liver disease undergoing cardiac catheterization.
Cardiac catheterization has been increasingly utilized to evaluate coronary artery disease in patients with end stage liver disease (ESLD). It is known in other populations that radial access reduces access site complications;however, there is a paucity of data in ESLD patients. We investigated vascular and bleeding complications rates between trans-femoral and trans-radial cardiac catheterizat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin
دوره 187 10 شماره
صفحات -
تاریخ انتشار 2015