Correlation between ORange® (Gen 1, pseudophakic) intraoperative refraction and 1-week postcataract surgery autorefraction

نویسنده

  • Ming Chen
چکیده

BACKGROUND This study aimed to find the strength of the correlation between ORange(®) (intraoperative wavefront aberrometer) objective refraction during pseudophakic cataract surgery (Gen 1) and 1-week objective autorefraction postcataract surgery in order to establish the clinical degree of confidence in the ORange. Gen 1 was used because Gen 2 was not available at the time of the study. However, Gen 1 can still be a good reference. METHODS Thirty-two consecutive eyes were included in this prospective nonrandomized study. ORange was used after phacoemulsification and intraocular lens implantation. There were no complications and no withdrawals from the study. The refraction data from the ORange were recorded in spherical equivalents and put into Excel. One week postoperatively, autorefraction was done and the data were again recorded in spherical equivalents and put into Excel. Both sets of data were then transferred to SPSS for a correlation study. Because ORange is an objective refractor, it is necessary to use another objective refractor, such as the Zeiss Autorefractor, for comparison. Measurement at 1 week postoperatively is for cornea clearance for autorefraction and is the closest time to intraoperative assessment for comparison. RESULTS The Pearson correlation was r = +0.56, P < 0.01, which qualifies for a moderate or good correlation (0.5-0.75). CONCLUSION Intraoperative refraction using the ORange Gen 1 after cataract surgery and intraocular lens implantation is moderate to good when correlated with objective autorefraction 1 week after cataract surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An evaluation of the accuracy of the ORange® (Gen II) by comparing it to the IOLMaster® in the prediction of postoperative refraction

PURPOSE The aim of this study was to evaluate the accuracy of ORange(®) Gen II (WaveTec Vision, Aliso Viejo, CA). SETTING The Surgical Suites, Honolulu, HI. METHODS The prospective 28 consecutive cataract surgical cases were selected from 85 cataract surgical cases between December 16, 2010 and February 24, 2011. With the same intraocular lens implantation, the predicted spherical equivalen...

متن کامل

Objective autorefraction in posterior chamber pseudophakia.

Automated refraction with the Canon RK-1 Autoref keratometer was evaluated in 110 eyes (110 patients) six to eight weeks after they had undergone extracapsular cataract extraction with posterior chamber intraocular lens implantation and achieved a best corrected visual acuity of at least 6/12. Autorefraction readings were obtained in 100 (91%) of these eyes. The agreement between autorefraction...

متن کامل

Autorefraction, Retinoscopy, Javal's Rule, and Grosvenor's Modified Javal's Rule: The Best Predictor of Refractive Astigmatism

The aim of the study was to determine the level of agreement between Javal's rule, autorefraction, retinoscopy, and refractive astigmatism and to determine which technique is the most suitable substitute when subjective refraction is not applicable using a clinical sample. A total of 36 subjects, 14 males and 22 females, were involved in this study. The intraclass correlation coefficients betwe...

متن کامل

Validity of autorefraction after cataract surgery with multifocal ReZoom intraocular lens implantation.

PURPOSE To evaluate the clinical utility of spherocylindrical automated refraction (AR) compared with subjective manifest refraction (MR) after cataract surgery with implantation of ReZoom refractive multifocal intraocular lenses (IOLs) (Advanced Medical Optics, Inc.). SETTING Private Practice. METHODS This prospective nonrandomized interventional study consisted of 72 patients with bilater...

متن کامل

The Boston keratoprosthesis provides a wide depth of focus.

PURPOSE To measure the through-focus curve for eyes implanted with a type 1 Boston keratoprosthesis (KPro) and compare it to that of pseudophakic controls with fixed pupil sizes. The results should assist in evaluating postoperative visual quality after surgery. They should also help to determine the necessary KPro inventories in terms of refractive power steps. METHODS Autorefraction and man...