Oxidative stress and inflammatory response increase during coronary artery bypass grafting with extracorporeal circulation.

نویسندگان

  • Flora Eli Melek
  • Liz Andréa Villela Baroncini
  • João Carlos Domingus Repka
  • Celso Soares Nascimento
  • Dalton Bertolim Précoma
چکیده

INTRODUCTION Thiobarbituric acid-reactive substance is a marker of oxidative stress and has cytotoxic and genotoxic actions. C- reactive protein is used to evaluate the acute phase of inflammatory response. OBJECTIVES To assess the thiobarbituric acid-reactive substance and C-reactive protein levels during extracorporeal circulation in patients submitted to cardiopulmonary bypass. METHODS Twenty-five consecutive surgical patients (16 men and nine women; mean age 61.2 ± 9.7 years) with severe coronary artery disease diagnosed by angiography scheduled for myocardial revascularization surgery with extracorporeal circulation were selected. Blood samples were collected immediately before initializing extracorporeal circulation, T0; in 10 minutes, T10; and in 30 minutes, T30. RESULTS The thiobarbituric acid-reactive substance levels increased after extracorporeal circulation (P=0.001), with average values in T0=1.5 ± 0.07; in T10=5.54 ± 0.35; and in T30=3.36 ± 0.29 mmoles/mg of serum protein. The C-reactive protein levels in T0 were negative in all samples; in T10 average was 0.96 ± 0.7 mg/dl; and in T30 average was 0.99 ± 0.76 mg/dl. There were no significant differences between the dosages in T10 and T30 (P=0.83). CONCLUSIONS C-reactive protein and thiobarbituric acid-reactive substance plasma levels progressively increased during extracorporeal circulation, with maximum values of thiobarbituric acid-reactive substance at 10 min and of C-reactive protein at 30 min. It suggests that there are an inflammatory response and oxidative stress during extracorporeal circulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bilateral Extracorporeal Circulation ("Drew Technique") for Coronary Artery Bypass Surgery using Patient's Lung as Oxygenator

The aim of this study was to determine: 1) whether a bilateral perfusion circuit (Drew technique) using the patient's own lung as the oxygenator is feasible for multi-vessel coronary artery bypass grafting; and 2) if the systemic inflammatory response to extracorporeal circulation differs compared to conventional cardiopulmonary bypass procedures. Twenty patients were enrolled in a randomized, ...

متن کامل

Oxidant Status following Cardiac Surgery with Phosphorylcholine-Coated Extracorporeal Circulation Systems

Introduction. Extracorporeal circulation (ECC) related systemic oxidative stress is a well-known entity but the underlying mechanisms are not clearly described. Our aim was to investigate the relation between the oxidative stress indices, inflammatory markers, and phosphorylcholine-coated (PCC) ECC systems. Patients and Methods. Thirty-two consecutive coronary artery bypass grafting (CABG) case...

متن کامل

Dynamics of Oxidative Stress Evoked by Myocardial Ischemia Reperfusion After Off-Pump Coronary Artery Bypass Grafting Elucidated by Bilirubin Oxidation.

BACKGROUND Revascularization therapy relieves myocardial ischemia, but can also result in ischemia-reperfusion injury caused by oxidative stress. However, the biokinetics of oxidative stress after myocardial ischemia-reperfusion are uncertain. This study aimed to evaluate the dynamics of oxidative stress after off-pump coronary artery bypass grafting (OPCAB) by measuring urinary biopyrrin level...

متن کامل

Reduction of pro-inflammatory cytokine levels and cellular adhesion in CABG procedures with separated pulmonary and systemic extracorporeal circulation without an oxygenator.

OBJECTIVE We have recently shown that a considerable amount of pro-inflammatory cytokines is released during pulmonary passage after aortic declamping in patients undergoing coronary artery bypass grafting. The present study was performed to investigate whether bilateral extracorporeal circulation with the lungs as oxygenators can reduce the inflammatory responses of the lungs. METHODS Eighte...

متن کامل

Mini extracorporeal circuit for coronary artery bypass grafting: initial clinical and biochemical results: a comparison with conventional and off-pump coronary artery bypass grafts concerning global oxidative stress and alveolar function.

BACKGROUND The new concept of mini-extracorporeal circulation (MECC) for coronary artery bypass grafts (MCABG) consists of minimal priming volume, a heparin-coated closed circuit, a centrifugal pump, active drainage, blood cardioplegia and a cell-saving device. The potential organ protective effect of this technique during CABG is unknown. Initial clinical outcomes, oxidative stress, alveolar s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista brasileira de cirurgia cardiovascular : orgao oficial da Sociedade Brasileira de Cirurgia Cardiovascular

دوره 27 1  شماره 

صفحات  -