Noise characteristics of single shot broadband Raman-resonant CARS with single- and multimode lasers: erratum.

نویسندگان

  • S Kroll
  • M Alden
  • T Berglind
  • R J Hall
چکیده

A simple model is presented as an aid in understanding, first, the relative noise performance and, second, the noise reduction achievable by referencing, in different experimental approaches to single shot broadband coherent anti-Stokes Raman scattering (CARS). Qualitative agreement is obtained with previous experimental investigations of CARS noise. The broadband dye laser radiation is described as the sum of independent modes with random phases. The dye laser contribution to the CARS noise is then approximately inversely proportional to the square root of the number of dye laser modes generating the detected signal. A fundamental idea is that in Raman resonant spectra only the number of Stokes modes actually participating in driving the Raman resonance should be counted. This means, e.g., that for narrow Raman resonances, as in an atmospheric flame, the noise generated by the dye laser will be higher for a single-mode pump laser than for a multimode pump laser with the experimental CARS configuration normally employed. The implications of the model for the dual broadband type CARS techniques are also discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Broadband coherent anti-Stokes Raman scattering spectroscopy of nitrogen using a picosecond modeless dye laser.

Broadband picosecond coherent anti-Stokes Raman scattering (CARS) spectroscopy of nitrogen is demonstrated using 145-ps pump and probe beams and a 115-ps Stokes beam with a spectral bandwidth of 5 nm. This is, to our knowledge, the first demonstration of broadband CARS using subnanosecond lasers. The short temporal envelope of the laser pulses and the broadband spectral nature of the Stokes bea...

متن کامل

High-resolution broadband N2 coherent anti-Stokes Raman spectroscopy: comparison of measurements for conventional and modeless broadband dye lasers.

We have performed high-resolution N2 coherent anti-Stokes Raman spectroscopy (CARS) measurements using a modeless dye laser (MDL) as the Stokes beam source to determine the effects of a reduction in mode noise on the accuracy and precision of the method. These results are compared with previous research that employed a conventional broadband dye laser (CBDL) as the Stokes beam source. A new spe...

متن کامل

Thermometry for turbulent flames by coherent anti-Stokes Raman spectroscopy with simultaneous referencing to the modeless excitation profile.

An optimal system for temperature measurements by coherent anti-Stokes Raman spectroscopy (CARS) in turbulent flames and flows is presented. In addition to a single-mode pump laser and a modeless dye laser, an echelle spectrometer with a cross disperser is used. This system permits simultaneous measurement of the N2 CARS spectrum and the broadband dye laser profile. A procedure is developed to ...

متن کامل

Rotational CARS: a comparison of different techniques with emphasis on accuracy in temperature determination.

Different rotational CARS techniques have been evaluated in terms of single-shot temperature accuracy and signal intensity in room temperature nitrogen and in flames. The different techniques include both dual broadband techniques, using one or two broadband dye lasers, and conventional rotational CARS with different dye lasers. These techniques are also compared with vibrational CARS concernin...

متن کامل

One-laser interferometric broadband coherent anti-Stokes Raman scattering.

We introduce an interferometric technique for eliminating the non-resonant background of broadband coherent anti-Stokes Raman scattering (CARS) microscopy. CARS microscopy has been used for imaging a number of biological samples and processes, but the studies are mostly limited to detecting lipids in biological systems by probing the C-H stretch. Non-resonant background and incoherent noise sou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 29 30  شماره 

صفحات  -

تاریخ انتشار 1987