One-year Outcome Evaluation after Interspinous Implantation for Degenerative Spinal Stenosis with Segmental Instability
نویسندگان
چکیده
The authors hypothesized that the placement of the interspinous implant would show a similar clinical outcome to the posterior lumbar interbody fusion (PLIF) in patients having spinal stenosis with mild segmental instability and that this method would be superior to PLIF without significantly affecting degeneration at the adjacent segments. Forty two adult patients having degenerative spinal stenosis with mild segmental instability who underwent implantation of Coflex (Spine motion, Germany) or PLIF at L4-5 between January 2000 and December 2003 were consecutively selected and studied for one-year clinical outcome. At 12 months after surgery, both groups showed a significant improvement in the visual analogue scale score and Oswestry disability index score for both lower extremity pain and low back pain. However, the range of motion at the upper adjacent segments (L3-4) increased significantly after surgery in the PLIF group, which was not manifested in the Coflex group during the follow-up. The authors assumed that interspinous implantation can be an alternative treatment for the spinal stenosis with segmental instability in selected conditions posing less stress on the superior adjacent level than PLIF.
منابع مشابه
Efficacy of an interspinous decompression device versus nonoperative treatment for lumbar spinal stenosis: an example for a randomized, controlled trial
Background: Lumbar spinal stenosis (LSS) with neurogenic intermittent claudication (NIC) is one of the most common degenerative spinal diseases in the elderly. One treatment option for LSS/neurogenic intermittent claudication is conservative management with oral analgesics, injections and physical therapy. Another relatively new operative alternative is interspinous process decompression. To da...
متن کاملLong-term Follow-up (Minimum 5 Years) Study of Single-level Posterior Dynamic Stabilization in Lumbar Degenerative Disease; 'Interspinous U' & 'DIAM'
OBJECTIVES Recently posterior dynamic stabilizations (PDS) are increased in degenerative lumbar disease. But, some previous studies had doubts its long term prognosis. Long term clinical and radiological results of PDS using interspinous device (Interspinous U, DIAM) were analyzed. METHODS We have used the 'interspinous U' and 'DIAM' for patients with lumbar spinal stenosis. We included singl...
متن کاملCombined laminoplasty with posterior lateral mass plate for unstable spondylotic cervical canal stenosis--technical note.
A technique of combined expanding laminoplasty using longitudinal interspinous iliac bone graft with posterior lateral mass plate is described for the treatment of cervical canal stenosis associated with spinal instability. A 52-year-old male and a 76-year-old female presented with cervical myelopathy. Imaging studies demonstrated spondylotic cervical canal stenosis associated with spinal insta...
متن کاملOne-Year Follow-Up of a Series of 100 Patients Treated for Lumbar Spinal Canal Stenosis by Means of HeliFix Interspinous Process Decompression Device
PURPOSE New interspinous process decompression devices (IPDs) provide an alternative to conservative treatment and decompressive surgery for patients with neurogenic intermittent claudication (NIC) due to degenerative lumbar spinal stenosis (DLSS). HeliFix is a minimally invasive IPD that can be implanted percutaneously. This is a preliminary evaluation of safety and effectiveness of this IPD u...
متن کاملSurgical results of dynamic nonfusion stabilization with the Segmental Spinal Correction System for degenerative lumbar spinal diseases with instability: Minimum 2-year follow-up
BACKGROUND When spinal fusion is applied to degenerative lumbar spinal disease with instability, adjacent segment disorder will be an issue in the future. However, decompression alone could cause recurrence of spinal canal stenosis because of increased instability on operated segments and lead to revision surgery. Covering the disadvantages of both procedures, we applied nonfusion stabilization...
متن کامل