Coronary flow reserve improves after aortic valve replacement for aortic stenosis: an adenosine transthoracic echocardiography study.

نویسندگان

  • D J Hildick-Smith
  • L M Shapiro
چکیده

OBJECTIVES The goal of this study was to assess coronary flow reserve (CFR) before and after aortic valve replacement (AVR). BACKGROUND Coronary flow reserve is impaired under conditions of left ventricular (LV) hypertrophy. It is not known whether CFR improves with regression of LV hypertrophy in humans. METHODS We investigated 35 patients with pure aortic stenosis, LV hypertrophy and normal coronary arteriograms. Patients underwent adenosine transthoracic echocardiography on two occasions--immediately before AVR and six months postoperatively. Left ventricular mass, distal left anterior descending coronary artery (LAD) diameter, flow and CFR were assessed on each occasion. RESULTS Distal LAD diameter was successfully imaged in 30 patients (86%), and blood flow was successfully imaged in 27 (77%). Paired data were subsequently available in 24 patients, of whom 14 were men, mean age 68.1+/-12.5 years, body mass index 24.5+/-2.0 kg/m2, aortic valve gradient 93+/-32 mm Hg. Pre- to post-AVR a significant decrease was seen in LV mass (271+/-38 vs. 236+/-32g, p<0.01) and LV mass index (154+/-21 vs. 134+/-21 g/m2, p< 0.01). Distal LAD diameter fell from 2.27+/-0.37 to 2.23+/-0.35 mm, p = 0.08). Pre- to post-AVR there was no significant change in resting parameters of peak diastolic velocity (0.43+/-0.16 vs. 0.41+/-0.11 m/s), distal LAD flow 23.3+/-10.1 vs. 20.9+/-5.2 ml/min or distal LAD flow scaled for LV mass (8.7+/-3.8 vs. 9.0+/-2.5 ml/min/100 g LV mass), but there was significant increase in hyperemic peak diastolic velocity (0.71+/-0.26 vs. 1.08+/-0.24 m/s; p<0.01), distal LAD flow (37.8+/-11.3 vs. 53.5+/-16.1 ml/min; p<0.01) and distal LAD flow scaled for LV mass (14.3+/-5.0 vs. 23.3+/-8.5 ml/min/100 g LV mass; p<0.01). Coronary flow reserve, therefore, increased from 1.76+/-0.5 to 2.61+/-0.7. CONCLUSIONS Coronary flow reserve increases after AVR for aortic stenosis. This increase occurs in tandem with regression of LV hypertrophy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The non-invasive documentation of coronary microcirculation impairment: role of transthoracic echocardiography

Transthoracic Doppler echocardiographic-derived coronary flow reserve is an useful hemodynamic index to assess dysfunction of coronary microcirculation. Isolated coronary microvascular abnormalities are overt by reduced coronary flow reserve despite normal epicardial coronary arteries. These abnormalities may occur in several diseases (arterial hypertension, diabetes mellitus, hypercholesterole...

متن کامل

Non-invasive measurement of coronary flow reserve in children with Kawasaki disease.

OBJECTIVE To investigate whether transthoracic Doppler echocardiography (TTE) can reliably measure the coronary flow reserve in the left anterior descending coronary artery in children with Kawasaki disease. DESIGN Coronary flow velocity in the distal left anterior descending coronary artery was measured by TTE and was compared with that obtained by intracoronary Doppler guide wire. The ratio...

متن کامل

Coronary artery stenosis in asymptomatic child after arterial switch operation: detection by transthoracic colour-flow doppler echocardiography.

UNLABELLED Arterial switch operation (ASO) has become the definitive anatomical correction for transposition of great arteries (TGA). Left coronary artery (LCA) ostial stenosis was detected by transthoracic Doppler echocardiography (TTDE) as a flame like colour flow diastolic signal and coronary flow reserve (CFR) was low, 1.3. It was treated successfully by a drug-eluted stent. These findings ...

متن کامل

Impact of patient-prosthesis mismatch and aortic valve design on coronary flow reserve after aortic valve replacement.

OBJECTIVES This prospective-randomized study investigated the effect of aortic valve design and patient-prosthesis mismatch (PPM) on coronary flow reserve (CFR) after mechanical or biological aortic valve replacement (AVR) in patients with aortic stenosis (AS). BACKGROUND Coronary flow reserve may be an important parameter of long-term survival after AVR in patients with AS. Reduced CFR may c...

متن کامل

Correlation Between Aortic Valve Sclerosis and Coronary Artery Disease: A Cross - Sectional Study

  Introduction: Aortic valve sclerosisis considered as a manifestation of coronary atherosclerosis. Recent studies demonstrated an association between aortic valve sclerosis and obstructive coronary artery disease. The purpose of this study was to evaluatethe correlation betweenaortic valve sclerosis andobstructive coronary artery disease and the extent of coronary artery disease in patients ho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 36 6  شماره 

صفحات  -

تاریخ انتشار 2000