Imaging Microscopic Features of Keratoconic Corneal Morphology

نویسندگان

  • Kate Grieve
  • Cristina Georgeon
  • Felipe Andreiuolo
  • Marie Borderie
  • Djida Ghoubay
  • Josette Rault
  • Vincent M. Borderie
چکیده

PURPOSE To search for gold-standard histology indicators using alternative imaging modalities in keratoconic corneas. METHODS Prospective observational case-control study. Fourteen keratoconic corneas and 20 normal corneas (10 in vivo healthy subjects and 10 ex vivo donor corneas) were examined. Images of corneas were taken by spectral domain optical coherence tomography (SD-OCT) and in vivo confocal microscopy (IVCM) before keratoplasty. The same removed corneal buttons were imaged after keratoplasty with full-field optical coherence microscopy (FFOCM) and then fixed and sent for histology. Controls consisted of normal subjects imaged in vivo with IVCM and donor corneas imaged ex vivo with FFOCM. Corneal structural changes related to pathology were noted with each imaging modality. Cell density was quantified by manual cell counting. RESULTS Keratoconus indicators (ie, epithelial thinning/thickening, cell shape changes, ferritin deposits, basement membrane anomalies, Bowman layer thinning, ruptures, interruptions, scarring, stromal modifications, and appearance of Vogt striae) were generally visible with all modalities. Additional features could be seen with FFOCM in comparison with gold-standard histology, particularly in the Bowman layer region, whereas the combination of SD-OCT plus IVCM detected 76% of those features detected in histology. Three-dimensional FFOCM imaging aided interpretation of two-dimensional IVCM and SD-OCT data. Basal epithelial cell and keratocyte densities were significantly lower in patients with keratoconus than those in normals (P < 0.0001). CONCLUSIONS Structural and cellular assessment of the keratoconic cornea by means of either in vivo SD-OCT combined with IVCM or ex vivo FFOCM in both cross-sectional and en face views can detect as many keratoconus indicators as gold-standard histology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corneal Cell Morphology in Keratoconus: A Confocal Microscopic Observation.

PURPOSE To evaluate corneal cell morphology in patients with keratoconus using an in vivo slit scanning confocal microscope. METHODS A cross-sectional study was conducted to evaluate the corneal cell morphology of 47 keratoconus patients and 32 healthy eyes without any ocular disease. New keratoconus patients with different disease severities and without any other ocular co-morbidity were rec...

متن کامل

Comparison of keratometric and pachymetric parameters with Scheimpflug imaging in normal and keratoconic Asian eyes

PURPOSE To evaluate the keratometric and pachymetric parameters of keratoconic corneas of Asian eyes with the Scheimpflug imaging camera. PATIENTS AND METHODS This is a cross-sectional study of 22 eyes with Amsler-Krumeich stage 1 keratoconus and 48 eyes from normal subjects conducted in a tertiary eye hospital. A rotating Scheimpflug imaging system, the Pentacam, was used to evaluate all eye...

متن کامل

Identifying more reliable parameters for the detection of change during the follow-up of mild to moderate keratoconus patients

Background Reaching a consensus on which parameters are most reliable at detecting progressive keratoconus patients with serial topography imaging is not evident. The aim of the study was to isolate the parameters best positioned to detect keratoconus progression using the Pentacam HR® measures based on the respective limits of repeatability and range of measurement. Method Using the Pentacam...

متن کامل

Correlation between epithelial thickness in normal corneas, untreated ectatic corneas, and ectatic corneas previously treated with CXL; is overall epithelial thickness a very early ectasia prognostic factor?

PURPOSE To determine and correlate epithelial corneal thickness (pachymetric) measurements taken with a digital arc scanning very high frequency ultrasound biomicroscopy (HF UBM) imaging system (Artemis-II), and compare mean and central epithelial thickness among normal eyes, untreated keratoconic eyes, and keratoconic eyes previously treated with collagen crosslinking (CXL). METHODS Epitheli...

متن کامل

Anterior Segment Optical Coherence Tomography: Assisted Topographic Corneal Epithelial Thickness Distribution Imaging of a Keratoconus Patient

PURPOSE To evaluate safety, efficacy and ease of measurement of epithelial thickness in a keratoconic patient based on anterior segment optical coherence tomography (AS-OCT). METHODS A 25-year-old male patient, previously diagnosed with keratoconus, with highly asymmetric manifestation among the two eyes, was subjected to AS-OCT corneal epithelial imaging. We investigated epithelial thickness...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 35  شماره 

صفحات  -

تاریخ انتشار 2016