Development of a vessel-mimicking material for use in anatomically realistic Doppler flow phantoms.

نویسندگان

  • Deirdre M King
  • Carmel M Moran
  • John D McNamara
  • Andrew J Fagan
  • Jacinta E Browne
چکیده

Polyvinyl alcohol cryogel (PVA-C) is presented as a vessel-mimicking material for use in anatomically realistic Doppler flow phantoms. Three different batches of 10% wt PVA-C containing (i) PVA-C alone, (ii) PVA-C with antibacterial agent and (iii) PVA-C with silicon carbide particles were produced, each with 1-6 freeze-thaw cycles. The resulting PVA-C samples were characterized acoustically (over a range 2.65 to 10.5 MHz) and mechanically to determine the optimum mixture and preparation for mimicking the properties of healthy and diseased arteries found in vivo. This optimum mix was reached with the PVA-C with antibacterial agent sample, prepared after two freeze/thaw cycles, which achieved a speed of sound of 1538 ± 5 m s(-1) and a Young's elastic modulus of 79 ± 11 kPa. This material was used to make a range of anatomically realistic flow phantoms with varying degrees of stenoses, and subsequent flow experiments revealed that higher degrees of stenoses and higher velocities could be achieved without phantom rupturing compared with a phantom containing conventional wall-less vessels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction

Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...

متن کامل

Wall-less Flow Phantom for High-Frequency Ultrasound Applications

There are currently very few test objects suitable for high-frequency ultrasound scanners that can be rapidly manufactured, have appropriate acoustic characteristics and are suitably robust. Here we describe techniques for the creation of a wall-less flow phantom using a physically robust konjac and carrageenan-based tissue-mimicking material. Vessel dimensions equivalent to those of mouse and ...

متن کامل

PIV-measured versus CFD-predicted flow dynamics in anatomically realistic cerebral aneurysm models.

Computational fluid dynamics (CFD) modeling of nominally patient-specific cerebral aneurysms is increasingly being used as a research tool to further understand the development, prognosis, and treatment of brain aneurysms. We have previously developed virtual angiography to indirectly validate CFD-predicted gross flow dynamics against the routinely acquired digital subtraction angiograms. Towar...

متن کامل

Acoustic resolution photoacoustic Doppler velocimetry in blood-mimicking fluids

Photoacoustic Doppler velocimetry provides a major opportunity to overcome limitations of existing blood flow measuring methods. By enabling measurements with high spatial resolution several millimetres deep in tissue, it could probe microvascular blood flow abnormalities characteristic of many different diseases. Although previous work has demonstrated feasibility in solid phantoms, measuremen...

متن کامل

Comparative imaging study in ultrasound, MRI, CT, and DSA using a multimodality renal artery phantom.

PURPOSE A range of anatomically realistic multimodality renal artery phantoms consisting of vessels with varying degrees of stenosis was developed and evaluated using four imaging techniques currently used to detect renal artery stenosis (RAS). The spatial resolution required to visualize vascular geometry and the velocity detection performance required to adequately characterize blood flow in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 37 5  شماره 

صفحات  -

تاریخ انتشار 2011