Delayed dislocation of a sutureless aortic bioprosthesis: the first case.
نویسندگان
چکیده
Sutureless aortic bioprosthesis implantation is an alternative technique in high-risk patients undergoing aortic valve replacement with a possible reduction in the extracorporeal circuit time and reliable haemodynamic features. A 3F Enable (ATS Medical-Medtronic, Inc., Minneapolis, MN, USA) has shown very good results. We report the first upward displacement of 3F Enable three months post implantation.
منابع مشابه
Valve-in-Valve Replacement Using a Sutureless Aortic Valve
BACKGROUND We present a unique case of a 61-year-old female patient with homograft deterioration after redo surgery for prosthetic valve endocarditis with root abscess. CASE REPORT The first operation was performed for type A dissection with root, arch, and elephant trunk replacement of the thoracic aorta. The present re-redo surgery was performed as valve-in-valve with a sutureless aortic biop...
متن کاملSutureless aortic valve replacement in stentless bioprosthesis failure.
Reoperation for a failed stentless bioprosthesis is an extremely challenging procedure due to severe adhesion around the previous stentless graft and the severely calcified aortic root. Although rarely the subject of reports in the literature, sutureless aortic valve replacement allows a fast and simple implantation, which decreases the risk of cardiac ischaemia and cardiopulmonary bypass. Here...
متن کاملSutureless aortic valve replacement in a calcified homograft combined with mitral valve replacement
BACKGROUND Aortic valve replacement in a patient with an aortic homograft can be very challenging, especially when concomitant mitral valve surgery needs to be performed. CASE PRESENTATION We report a case of implantation of a sutureless aortic valve bioprosthesis combined with mitral valve replacement in a patient with a severely calcified aortic homograft where conventional valve replacemen...
متن کاملExperimental Study and Early Clinical Application Of a Sutureless Aortic Bioprosthesis
INTRODUCTION The conventional aortic valve replacement is the treatment of choice for symptomatic severe aortic stenosis. Transcatheter technique is a viable alternative with promising results for inoperable patients. Sutureless bioprostheses have shown benefits in high-risk patients, such as reduction of aortic clamping and cardiopulmonary bypass, decreasing risks and adverse effects. OBJECT...
متن کاملA Tricky Percutaneous Paravalvular Leak Closure Two Years After Implantation of 3f Enable Sutureless Bioprosthetic Aortic Valve.
Sutureless valves were designed in an attempt to simplify the aortic valve replacement procedure and reduce extracorporeal circuit time, whilst allowing complete excision of the calcified native valve using a minimally invasive approach. Elderly patients with significant comorbidities are considered to benefit the most, although randomized data are lacking. In registries of patients treated wit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Interactive cardiovascular and thoracic surgery
دوره 14 6 شماره
صفحات -
تاریخ انتشار 2012