Assessment of Effective Thermal Product of Surface Junction Thermocouples on Millisecond and Microsecond Time Scales

نویسنده

  • D. R. Buttsworth
چکیده

Surface junction thermocouples are used extensively for transient heat flux measurements, but their accuracy is dependent on the effective thermal product (TP) of the gauge and this can be a function of the time scale of interest. In the present work the response of surface junction k-type thermocouples was investigated experimentally using a water droplet calibration technique (for millisecond times scales) and a small shock tube (for microsecond time scales). Different junctions formed by scalpel blade scratches and abrasive paper were investigated. When scratches from scalpel blades were used to form the junction, the TP identified from the water droplet calibrations consistently differs by approximately 20 % depending on whether the junction was made on the chromel or alumel substrate, in accord with existing thermal properties data. However, the shock tube calibrations indicate that for scalpel-scratched junctions there is considerable variability in thermocouple response time due to effective junction depth variations produced during construction. In contrast, junctions formed with abrasive paper produced rise times consistently less than 1 μs, but the water droplet and shock tube experiments both indicated significant variability in the effective TP for these gauges. The consistency in TP for scalpel-scratched junctions for millisecond time scales and the variability for junctions created with abrasive grit for both the millisecond and microsecond time scales is attributed to the differences in the effective proximity of the junction to the insulation between chromel and alumel substrates. For junctions created with abrasive grit, the effective TP is approximately 30 % smaller for microsecond time scales than it is for millisecond time scales.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extending the range of microsecond-to-millisecond chemical exchange detected in labeled and unlabeled nucleic acids by selective carbon R(1rho) NMR spectroscopy.

We present an off-resonance carbon R(1rho) NMR experiment utilizing weak radiofrequency fields and selective polarization transfers for quantifying chemical-exchange processes in nucleic acids. The experiment extends the range of accessible time scales to approximately 10 ms, and its time-saving feature makes it possible to thoroughly map out dispersion profiles and conduct measurements at natu...

متن کامل

Microsecond time-resolved energy-dispersive EXAFS measurement and its application to film the thermolysis of (NH4)2[PtCl6]

Microsecond (μs) time-resolved extended X-ray absorption fine structure spectroscopy (EXAFS) has been developed using an energy-dispersive EXAFS (EDE) setup equipped with a silicon Quantum Detector ULTRA. The feasibility was investigated with a prototypical thermally driven redox reaction, the thermal decomposition of (NH₄)₂[PtCl₆]. EXAFS data were collected with snapshots every 60 μs during th...

متن کامل

Modeling of Effective Thermal Conductivity and Viscosity of Carbon Structured Nanofluid

This paper was aimed to address the modeling of effective thermal conductivity and viscosity of carbon structured nanofluids. Response surface methodology, D_optimal design (DOD) was employed to assess the main and interactive effects of temperature (T) and weight percentage (wt %) to model effective thermal conductivity and viscosity of multi wall and single wall carbon nanotube, CVD and RGO G...

متن کامل

Influence of Interface Thermal Resistance on Relaxation Dynamics of Metal-Dielectric Nanocomposite Materials under Ultrafast Pulse Laser Excitation

Nanocomposite materials, including noble metal nanoparticles embedded in a dielectric host medium, are interesting because of their optical properties linked to surface plasmon resonance phenomena. For studding of nonlinear optical properties and/or energy transfer process, these materials may be excited by ultrashort pulse laser with a temporal width varying from some femtoseconds to some hund...

متن کامل

Predictive values of Braden and waterlow scales to assess the risk of pressure ulcer : Review article

Introduction: Pressure ulcer is a kind of skin disorder that is developed due to increase of localized pressure on a part of body. Due to the terrible consequences of pressure ulcer, it is essential to prevent it. A common method to prevent is using risk assessment scales. The aim of this review study is to identify the best risk assessment to prevent and reduce the incidence of pressure ulcer....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007