Electrocardiogram-gated intravascular ultrasound image acquisition after coronary stent deployment facilitates on-line three-dimensional reconstruction and automated lumen quantification.
نویسندگان
چکیده
OBJECTIVE This study evaluates the feasibility, reliability and reproducibility of electrocardiogram (ECG)-gated intravascular ultrasound (IVUS) image acquisition during automated transducer withdrawal and automated three-dimensional (3D) boundary detection for assessing on-line the result of coronary stenting. BACKGROUND Systolic-diastolic image artifacts frequently limit the clinical applicability of such automated analysis systems. METHODS In 30 patients, after successful angiography-guided implantation of 34 stents in 30 target lesions, we carried out IVUS examinations on-line with the use of ECG-gated automated 3D analyses and conventional manual analyses of two-dimensional images from continuous pullbacks. These on-line measurements were compared with off-line 3D reanalyses. The adequacy of stent deployment was determined by using ultrasound criteria for stent apposition, symmetry and expansion. RESULTS Gated image acquisition was successfully performed in all patients to allow on-line 3D analysis within 8.7 +/- 0.6 min (mean +/- SD). Measurements by on-line and off-line 3D analyses correlated closely (r > or = 0.95), and the minimal stent lumen differed only minimally (8.6 +/- 2.8 mm2 vs. 8.5 +/- 2.8 mm2, p = NS). The conventional analysis significantly overestimated the minimal stent lumen (9.0 +/- 2.7 mm2, p < 0.005) in comparison with results of both 3D analyses. Fourteen stents (41%) failed to meet the criteria by both 3D analyses, all of these not reaching optimal expansion, but only 7 (21%) were detected by conventional analysis (p < 0.02). Intraobserver and interobserver comparison of stent lumen measurements by the automated approach revealed minimal differences (0.0 +/- 0.2 mm2 and 0.0 +/- 0.3 mm2) and excellent correlations (r = 0.99 and 0.98, respectively). CONCLUSIONS ECG-gated image acquisition after coronary stent deployment is feasible, permits on-line automated 3D reconstruction and analysis and provides reliable and reproducible measurements; these factors facilitate detection of the minimal lumen site.
منابع مشابه
Usefulness of three-dimensional reconstruction for interpretation and quantitative analysis of intracoronary ultrasound during stent deployment.
We examined 49 coronary stents in 33 patients after angiographically guided optimization of the deployment by intracoronary ultrasound, and compared the findings of a conventional 2-dimensional analysis approach with the results obtained from an automatic lumen recognition provided by a 3-dimensional reconstruction system. The automatic lumen analysis demonstrated that only 15 stents (31%) fulf...
متن کاملOptimization of Stent Deployment by Intravascular Ultrasound
Intravascular ultrasound (IVUS) is a useful diagnostic method that provides valuable information in addition to angiography regarding the coronary vessel lumen, dimensions, plaque burden, and characteristics. The major use of IVUS in coronary intervention is to guide interventional strategies and assess optimal stent deployment. Since the introduction of the drug-eluting stent (DES), concerns a...
متن کاملA New 3-D Automated Computational Method to Evaluate In-Stent Neointimal Hyperplasia in In-Vivo Intravascular Optical Coherence Tomography Pullbacks
Detection of stent struts imaged in vivo by optical coherence tomography (OCT) after percutaneous coronary interventions (PCI) and quantification of in-stent neointimal hyperplasia (NIH) are important. In this paper, we present a new computational method to facilitate the physician in this endeavor to assess and compare new (drug-eluting) stents. We developed a new algorithm for stent strut det...
متن کاملIntravascular ultrasound after low and high inflation pressure coronary artery stent implantation.
OBJECTIVES We sought to characterize the differences seen after low or high pressure coronary artery stent deployment as assessed by intravascular ultrasound. BACKGROUND Until 1992, the success of stent deployment was assessed by angiographic criteria only, but in 1993 the procedure was expanded to include postprocedural single-use intravascular ultrasound imaging. Ultrasound criteria for suc...
متن کامل3D Reconstruction of Coronary Stents in Vivo Based on Motion Compensated X-Ray Angiograms
A new method is introduce for the three-dimensional (3D) reconstruction of the coronary stents in-vivo utilizing two-dimensional projection images acquired during rotational angiography (RA). The method is based on the application of motion compensated techniques to the acquired angiograms resulting in a temporal snapshot of the stent within the cardiac cycle. For the first time results of 3D r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 30 2 شماره
صفحات -
تاریخ انتشار 1997