Optical patient interface in femtosecond laser-assisted cataract surgery: contact corneal applanation versus liquid immersion.

نویسندگان

  • Jonathan H Talamo
  • Philip Gooding
  • David Angeley
  • William W Culbertson
  • Georg Schuele
  • Daniel Andersen
  • George Marcellino
  • Emma Essock-Burns
  • Juan Batlle
  • Rafael Feliz
  • Neil J Friedman
  • Daniel Palanker
چکیده

PURPOSE To compare 2 optical patient interface designs used for femtosecond laser-assisted cataract surgery. SETTING Optimedica Corp., Santa Clara, California, USA, and Centro Laser, Santo Domingo, Dominican Republic. DESIGN Experimental and clinical studies. METHODS Laser capsulotomy was performed during cataract surgery with a curved contact lens interface (CCL) or a liquid optical immersion interface (LOI). The presence of corneal folds, incomplete capsulotomy, subconjunctival hemorrhage, and eye movement during laser treatment were analyzed using video and optical coherence tomography. The induced rise of intraocular pressure (IOP) was measured in porcine and cadaver eyes. RESULTS Corneal folds were identified in 70% of the CCL cohort; 63% of these had areas of incomplete capsulotomies beneath the corneal folds. No corneal folds or incomplete capsulotomies were identified in the LOI cohort. The mean eye movement during capsulotomy creation (1.5 sec) was 50 μm with a CCL and 20 μm with an LOI. The LOI cohort had 36% less subconjunctival hemorrhage than the CCL cohort. During suction, the mean IOP rise was 32.4 mm Hg ± 3.4 (SD) in the CCL group and 17.7 ± 2.1 mm Hg in the LOI group. CONCLUSIONS Curved contact interfaces create corneal folds that can lead to incomplete capsulotomy during laser cataract surgery. A liquid interface eliminated corneal folds, improved globe stability, reduced subconjunctival hemorrhage, and lowered IOP rise.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of intra-ocular pressure changes with liquid or flat applanation interfaces in a femtosecond laser platform

Cataract surgery is the most common surgical procedure and femtosecond laser assisted cataract surgery (FLACS) has gained increased popularity. FLACS requires the application of a suction device to stabilize the laser head and focus the laser beam accurately. This may cause a significant escalation in intra-ocular pressure (IOP), which poses potential risks for patients undergoing cataract surg...

متن کامل

Femtosecond laser-assisted cataract surgery versus standard phacoemulsification cataract surgery: outcomes and safety in more than 4000 cases at a single center.

PURPOSE To compare the intraoperative complications and safety of femtosecond laser-assisted cataract surgery and conventional phacoemulsification cataract surgery. SETTING Single center. DESIGN Prospective consecutive comparative cohort case series. METHODS Eyes had femtosecond laser-assisted cataract surgery (study group) or phacoemulsification (control group) by 1 of 5 surgeons. The te...

متن کامل

Comparative analysis of the performance of two different platforms for femtosecond laser-assisted cataract surgery

PURPOSE To analyze and compare the intraoperative and postoperative outcomes of cataract surgery performed with two different femtosecond laser platforms. METHODS Randomized controlled prospective intraindividual comparative study including 90 eyes of 45 patients aged between 61 and 86 years. All eyes underwent bilateral cataract surgery assisted with femtosecond laser technology. Eyes were r...

متن کامل

Femtosecond laser-assisted cataract surgery after penetrating keratoplasty: a case report

BACKGROUND Cataract surgery after penetratingkeratoplasty (PKP) is often challenging due to changes in the integrity of the cornea caused by PKP. For example, corneal endothelial cell (CEC) loss and corneal edema commonly occur after traditional phacoemulsification cataract surgery in patients that previously had successful PKP. Recent studies have reported that femtosecond laser-assisted catar...

متن کامل

Application of Corvis ST to evaluate the effect of femtosecond laser-assisted cataract surgery on corneal biomechanics

The aim of the present study was to evaluate the effects of femtosecond laser-assisted cataract surgery (FLACS) and phacoemulsification on corneal biomechanics using corneal visualization Scheimpflug technology. The medical records of 50 eyes from 50 patients who received phacoemulsification and intraocular lens implantation because of age-related factors between June 2014 and September 2014 we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 39 4  شماره 

صفحات  -

تاریخ انتشار 2013